N3K-C3064TQ-10GT is the Nexus 3064-T, 48 10GBase-T, and 4 QSFP+ ports. The Cisco Nexus 3064-X, 3064-T, and 3064-32T Switches are high-performance, high-density Ethernet switches that are part of the Cisco Nexus 3000 Series Switches portfolio. These compact one-rack-unit (1RU) form-factor 10 Gigabit Ethernet switches provide line-rate Layer 2 and 3 switching. They run the industry-leading Cisco NXOS Software operating system, providing customers with comprehensive features and functions that are widely deployed globally. They support both forward and reverse airflow schemes with AC and DC power inputs. The Cisco Nexus 3064 switches are well suited for data centers that require cost-effective, power-efficient, line-rate Layer 2 and 3 top-of-rack (ToR) switches.
Table 1 shows the Quick Specs.
Product Code |
|
Physical |
1RU fixed form factor Cisco Nexus 3064-T: 64 x 10 Gigabit Ethernet ports (48 10GBASE-T and 4 QSFP+) 48 RJ-45 ports support 100 Mbps and 1 and 10 Gigabit Ethernet 4 QSFP ports support 4 x 10 Gigabit Ethernet or 40 Gigabit Ethernet each 2 redundant power supplies 1fan tray with redundant fans 1 I/O module with management, console, and USB flash memory ports |
Performance |
1.28-Tbps switching capacity Forwarding rate of 950 mpps Line-rate traffic throughput (both Layer 2 and 3) on all ports Configurable maximum transmission units (MTUs) of up to 9216 bytes (jumbo frames) |
Physical dimensions |
1.72 x 17.3 x 22.45 in.(4.4 x 43.9 x 57.0 cm) |
Weight |
20.8 lb (9.5 kg) |
The Cisco Nexus 3064 switches provide the following main benefits:
(1) The QSFP28 port can be configured to work as 4 x 25-Gbps ports, offering deployment flexibility, with up to a maximum of 128 x 25-Gbps ports.
(2) Both fiber and copper cabling solutions are available for 10-, 25-, 40-, 50-, and 100-Gbps connectivity, including active optical cable (AOC) and direct-attached cable (DAC).
(1) Virtual PortChannel (vPC) technology provides Layer 2 multipathing through the elimination of the Spanning Tree Protocol. It also enables fully utilized bisectional bandwidth and simplified Layer 2 logical topologies without the need to change the existing management and deployment models.
(2) The 64-way equal-cost multipath (ECMP) routing enables the use of Layer 3 fat-tree designs. This feature allows organizations to prevent network bottlenecks, increase resiliency, and add capacity with little network disruption.
(3) Advanced reboot capabilities include hot and cold patching and fast reboot capabilities.
(4) The switch uses hot-swappable power-supply units (PSUs) and fans.
(1) Power-on auto-provisioning (POAP) enables touchless bootup and configuration of the switch, drastically reducing provisioning time.
(2) Cisco Embedded Event Manager (EEM) and Python scripting enable automation and remote operations in the data center.
(3) Advanced buffer monitoring reports real-time buffer utilization per port and per queue, which allows organizations to monitor traffic bursts and application traffic patterns.
(4) EtherAnalyzer is a built-in packet analyzer for monitoring and troubleshooting control-plane traffic and is based on the popular Wireshark open-source network protocol analyzer.
(5) Complete Layer 3 unicast and multicast routing protocol suites are supported, including Border Gateway Protocol (BGP), Open Shortest Path First (OSPF), Enhanced Interior Gateway Routing Protocol (EIGRP), Routing Information Protocol Version 2 (RIPv2), Protocol Independent Multicast sparse mode (PIM-SM), Source-Specific Multicast (SSM), and Multicast Source Discovery Protocol (MSDP).
Table 2 shows the supported accessories.
Model |
Description |
QSFP to 4xSFP10G passive copper splitter cable, 5m |
|
QSFP to 4xSFP10G passive copper splitter cable, 3m |
|
QSFP to 4xSFP10G passive copper splitter cable, 1m |
|
Cisco 40GBASE-CR4 QSFP+ direct-attach copper cable, 10m, active |
|
Cisco 40GBASE-CR4 QSFP+ direct-attach copper cable, 7m, active |
|
40GBASE-CR4 passive copper cable, 5m |
|
40GBASE-CR4 passive copper cable, 3m |
|
40GBASE-CR4 passive copper cable, 1m |
|
40GBASE-SR4 QSFP transceiver module with MPO connector |
|
Cisco 40GBASE-CSR4 transceiver module, MPO, 300m |
|
QSFP 40GBASE-LR4 QSFP+ module for SMF |
|
10GBASE-SR SFP+ module (multimode fiber [MMF]) |
|
10GBASE-LR SFP+ module (single-mode fiber [SMF]) |
|
Cisco 10GBASE-ER SFP+ module for SMF |
|
Cisco 10GBASE-ZR SFP+ module for SMF |
|
1000BASE-T SFP |
|
GE SFP, LC connector SX transceiver (MMF) |
|
GE SFP, LC connector LX/LH transceiver (SMF) |
|
1000BASE-T SFP |
|
Nexus 3064 Fan Module, Forward airflow (port side exhaust) |
|
Nexus 3064 Fan Module, Reversed airflow (port side intake) |
|
N2K/3K 400W AC Power Supply, Forward airflow (port side exhaust) |
|
N2K/3K 400W AC Power Supply, Reversed airflow (port side intake) |
|
Nexus 3064-T 500W AC PSU, Forward airflow (port side exhaust) |
|
N2K/3K 400W DC Power Supply, Forward airflow (port side exhaust) |
|
N3K Series 350W DC Power Supply, Reversed airflow (port side intake) |
|
Nexus 3000 LAN Enterprise License, eDelivery |
Table 3 shows the comparison.
Product Code |
||
Ports |
32 QSFP 40 Gbps Ports. Each QSFP port supports 4 x 10 Gigabit Ethernet or 40 Gigabit Ethernet |
48 RJ-45 ports support 100 Mbps and 1 and 10 Gigabit Ethernet 4 QSFP ports support 4 x 10 Gigabit Ethernet or 40 Gigabit Ethernet each |
Physical dimensions |
1.72 x 17.3 x 19.7 in. (4.4 x 43.9 x 50.5 cm) |
1.72 x 17.3 x 22.45 in.(4.4 x 43.9 x 57.0 cm) |
Weight |
18.8 lb (8.5 kg) |
20.8 lb (9.5 kg) |
Do you have any question about the Cisco N3K-C3064TQ-10GT?
Contact us now via Live Chat or Contact@huatenmax.com.
N3K-C3064TQ-10GT Specification |
||
Physical |
● 1RU fixed form factor ● Cisco Nexus 3064-T: 64 x 10 Gigabit Ethernet ports (48 10GBASE-T and 4 QSFP+) ◦ 48 RJ-45 ports support 100 Mbps and 1 and 10 Gigabit Ethernet ◦ 4 QSFP ports support 4 x 10 Gigabit Ethernet or 40 Gigabit Ethernet each ● 2 redundant power supplies ● 1fan tray with redundant fans ● 1 I/O module with management, console, and USB flash memory ports |
|
Performance |
● 1.28-Tbps switching capacity ● Forwarding rate of 950 mpps ● Line-rate traffic throughput (both Layer 2 and 3) on all ports ● Configurable maximum transmission units (MTUs) of up to 9216 bytes (jumbo frames) |
|
Hardware tables and scalability |
MAC addresses |
128,000 |
Number of VLANS |
4096 |
|
Spanning-tree instances |
● Rapid Spanning Tree Protocol (RSTP): 512 ● Multiple Spanning Tree (MST) Protocol: 64 |
|
ACL entries |
● 2000 ingress ● 1000 egress |
|
Routing table |
● 16,000 prefixes and 16,000 host entries ● 8000 multicast routes |
|
Number of EtherChannels |
64 (with vPC) |
|
Number of ports per EtherChannel |
32 |
|
Buffers |
9 MB shared |
|
Boot flash memory |
2 GB |
|
Power |
Number of power supplies |
2 ● Cisco 3064-T and 3064-32T: Redundant for AC power |
Power supply types |
● AC (forward and reversed airflow) ● DC (forward and reversed airflow) |
|
Typical operating power |
● CiscoNexus 3064-T ◦ 362W (48p with 3m cables; 4 SR4 at 100% load) |
|
AC PSUs ● Input voltage ● Frequency ● Efficiency |
● 100 to 240 VAC ● 50 to 60 Hz ● 89 to 91% at 220V |
|
DC PSUs ● Input voltage ● Maximum current ● Efficiency |
● -40 to -72 VDC ● 33A ● 85 to 88% |
|
Typical heat dissipation |
● Cisco Nexus 3064-T ◦ 1235 BTU/hr (48p with 3m cables; 4 SR4 at 100% load) |
|
Maximum heat dissipation |
● Cisco Nexus 3064-T: 1553 BTU/hr |
|
Cooling |
Forward and reversed airflow schemes: ● Forward airflow: Port-side exhaust (air enters through fan-tray and power supplies and exits through ports) ● Reversed airflow: Port-side intake (air enters through ports and exits through fan-tray and power supplies) Single fan tray with redundant fans Hot swappable (must swap within 1 min) |
|
Sound |
Measured sound power (maximum) ● Fan speed: 40% duty cycle ● Fan speed: 60% duty cycle ● Fan speed: 100% duty cycle |
● 59.7 dBA ● 66.4 dBA ● 71.0 dBA |
Environment |
Dimensions (height x width x depth) |
● Cisco Nexus 3064-T and 3064-32T: 1.72 x 17.3 x 22.45 in.(4.4 x 43.9 x 57.0 cm) |
Weight |
● Cisco Nexus 3064-T and 3064-32T: 20.8 lb (9.5 kg) |
|
Operating temperature |
32 to 104°F (0 to 40°C) |
|
Storage temperature |
-40 to 158°F (-40 to 70°C) |
|
Operating relative humidity |
● 10 to 85% noncondensing ● Up to 5 days at maximum (85%) humidity ● Recommend ASHRAE data center environment |
|
Storage relative humidity |
5 to 95% noncondensing |
|
Altitude |
0 to 10,000 ft (0 to 3000m) |