ET1BS12712S0 is the Huawei S12712 Switch assembly chassis, including 12 slots.
Figure 1 shows the S12712 appearance. ET1BS12712S0 is its assembly chassis, including no cards, modules or units.
Table 1 shows the Quick Specs.
Product Code |
|
Packet Forwarding Rates |
9,120 Mpps; 12,960 Mpps(With Necessary Plug-ins) |
Switching Capacity |
17.44 Tbit/s; 44.96 Tbit/s(With Necessary Plug-ins) |
MPU Slots |
2 |
SFU Slots |
4 |
Service Card Slots |
12 |
Energy Saving |
Energy Efficient Ethernet (802.3az) |
Redundancy Design |
MPUs, SFUs, power supplies, and fan modules |
Maximum Power Consumption of the Entire Equipment |
≤ 6,600W |
Dimensions (W x D x H) |
With cable management frames: 442 mm x 585 mm x 841.75 mm (17.4 in. x 23.0 in. x 33.1 in. (19 U)) Without cable management frames: 442 mm x 489 mm x 841.75 mm (17.4 in. x 19.3 in. x 33.1 in. (19 U)) |
Weight |
63 kg |
Figure 2 shows the front structure of the ET1BS12712S0.
Note:
① |
Two MPUs |
② |
Twelve service cards, including: ·Open Service Platform Unit·1000M Interface Card ·GE/10GE Interface Card ·10GE Interface Card ·40GE Interface Card ·100GE Interface Card |
③ |
Four SFUs |
④ |
A pair of mounting brackets |
⑤ |
Six power modules |
⑥ |
Two CMUs |
⑦ |
Front ESD jack |
⑧ |
Cable management frames |
·The ET1BS12712S0 is just a Chassis that it doesn't provide cards, modules or units. The cards, modules or units must be purchased separately.
·The mounting brackets are used to secure the chassis in a cabinet.
·The ground terminal of an ESD wrist strap can be inserted in this jack. The ESD wrist strap can provide ESD protection when the chassis is reliably grounded.
·The cable management frames separate cables on different cards and help route cables orderly.
Figure 3 shows the rear structure of the ET1BS12712S0.
Note:
① |
Five Fan Modules |
② |
Rear ESD jack |
③ |
JG ground terminal |
④ |
A pair of handles |
⑤ |
Air filter |
·The ground terminal of an ESD wrist strap can be inserted in this jack. The ESD wrist strap can provide ESD protection when the chassis is reliably grounded.
·The handles are only used for this purpose: After you lift the chassis onto the guide rails or tray, grasp the handles to drag the chassis into the cabinet.
·The air filter prevents dust from entering the chassis.
Table 2 shows the recommended elements for the ET1BS12712S0.
Model |
Description |
FE-SFP optical transceiver |
|
Optical Transceiver, SFP, 100M/155M, Multi-mode Module(1310nm, 2km, LC) |
|
Optical Transceiver, eSFP, 100M/155M, Single-mode Module(1310nm, 15km, LC) |
|
Optical Transceiver, eSFP, FE, Single-mode Module(1310nm, 40km, LC) |
|
GE-SFP optical transceiver |
|
Optical Transceiver, eSFP, GE, Multi-mode Module(850nm, 0.55km, LC) |
|
Optical Transceiver, eSFP, GE, Single-mode Module(1310nm, 10km, LC) |
|
Optical Transceiver, eSFP, GE, Single-mode Module(1310nm, 40km, LC) |
|
Optical Transceiver, eSFP, GE, Single-mode Module(1550nm, 40km, LC) |
|
10G-SFP+ optical transceiver |
|
10GBase-USR Optical Transceiver, SFP+, 10G, Multi-mode Module(850nm, 0.1km, LC) |
|
Optical Transceiver, SFP+, 10G, Multi-mode Module(850nm, 0.3km, LC) |
|
Optical Transceiver, SFP+, 10G, Single-mode Module(1310nm, 10km, LC) |
|
40GE CFP optical transceiver |
|
High Speed Transceiver CFP-40G-SR4,CFP,40G,Multimode Module(850nm,4*10G,0.1km,MPO) |
|
High Speed Transceiver,CFP,40G,Single-mode Module(1310nm band,41.25G,10km,stright LC) |
|
|
High Speed Transceiver,CFP,40G,Single-mode Module(1310nm band,41.25G,40km,stright LC) |
40GE QSFP+ optical transceiver |
|
|
40GBase-eSR4 Optical Transceiver,QSFP+,40G,Multi-mode (850nm,0.3km,MPO)(Connect to four SFP+ Optical Transceiver) |
|
40GBase-ER4 Optical Transceiver,QSFP+,40G,Single-mode Module (1310nm,40km,LC) |
100GE CFP optical transceiver |
|
|
High Speed Transceiver,CFP,100G,Multimode Module(850nm,10*10G,0.1km,MPO) |
|
CFP, 100G, Single-mode Module(1310nm band,4*25G,10km,stright LC) |
|
High Speed Transceiver,CFP,100G,Single-mode Module(1310nm band,4*25G,40km,stright LC) |
GE copper transceiver |
|
Electrical Transceiver,SFP,GE,Electrical Interface Module(100m,RJ45) |
|
100GE interface card |
|
|
2-Port 100GBASE-X Interface Card(EE,CFP) ET1D2C02FEE0series) |
10GE interface card |
|
|
32-Port 10GBASE-X Interface Card(SC,SFP+) |
|
12-Port 10GBASE-X Interface Card(SA,SFP+) |
40GE interface card |
|
|
8-Port 40GBASE-X Interface Card(SC,QSFP+) |
|
2-Port 40GBASE-X Interface Card(SC,QSFP+) |
Centralized monitoring unit |
|
|
Centralized Monitoring Board |
Cluster switching system unit |
|
|
8-Port 10G Cluster Switching System Service Unit (SFP+) |
Firewall module |
|
|
NGFW Module C,with HW General Security Platform Software |
|
NGFW Module B,with HW General Security Platform Software |
GE/10GE interface card |
|
|
8-Port 10GBASE-X and 8-Port 100/1000BASE-X and 8-Port 10/100/1000BASE-T Combo Interface Card(X1E,RJ45/SFP/SFP+) |
|
4-Port 10GBASE-X and 24-Port 100/1000BASE-X and 8-Port 10/100/1000BASE-T Combo Interface Card(X1E,RJ45/SFP/SFP+) |
Intrusion prevention system module |
|
|
IPS Module A,with HW General Security Platform Software |
Main processing unit |
|
|
S12708/S12712,Main Processing Unit A(Optional clock) |
Switch fabric unit |
|
|
S12708/S12712,Switch Fabric Unit D |
|
S12708/S12712,Switch Fabric Unit A |
Wireless access controller unit |
|
|
WLAN ACU2 Access Controller Unit(128 AP Control Resource Included) |
GE interface card |
|
|
36-Port 10/100/1000BASE-T and 12-Port 100/1000BASE-X Interface Card(EA,RJ45/SFP) |
|
48-Port 100/1000BASE-X Interface Card(X1E,SFP) |
Table 3 shows the comparison of ET1BS12712S0 and ET1BS12708S0.
Product Code |
||
Description |
Huawei S12712 Switch assembly chassis |
Huawei S12708 Switch assembly chassis |
Packet Forwarding Rates |
9,120 Mpps; 12,960 Mpps(With Necessary Plug-ins) |
6,240 Mpps; 9,120 Mpps(With Necessary Plug-ins) |
Switching Capacity |
17.44 Tbit/s; 44.96 Tbit/s(With Necessary Plug-ins) |
12.32 Tbit/s; 32.16 Tbit/s(With Necessary Plug-ins) |
MPU Slots |
2 |
2 |
SFU Slots |
4 |
4 |
Service Card Slots |
12 |
8 |
Maximum Power Consumption of the Entire Equipment |
≤ 6,600W |
≤ 4,400W |
Weight |
63 kg |
42 kg |
Do you have any question about the ET1BS12712S0?
Contact us now via Live Chat or Contact@huatenmax.com.
ET1BS12712S0 Specification |
|
Switching Capacity |
17.44 Tbit/s; 44.96 Tbit/s |
Packet Forwarding Rates |
9,120 Mpps; 12,960 Mpps |
MPU Slots |
2 |
SFU Slots |
4 |
Service Card Slots |
12 |
Redundancy Design |
MPUs, SFUs, power supplies, and fan modules |
CSS2 |
1+N backup of MPUs in a cluster |
Up to 1.92 Tbit/s cluster bandwidth, 4 μs inter-chassis transmission latency |
|
Wireless Network Management |
Native AC |
AP access control, AP region management, and AP profile management |
|
Radio profile management, uniform static configuration, and centralized dynamic management |
|
Basic WLAN services, QoS, security, and user management |
|
User Management |
Unified user management |
802.1x, MAC, and Portal authentication |
|
Traffic- and time-based accounting |
|
User authorization based on user groups, domains, and time ranges |
|
iPCA Quality Awareness |
Marking real service packets to obtain real-time count of dropped packets and packet loss ratio |
Counting number of dropped packets and packet loss ratio on devices and L2/L3 networks |
|
SVF2.0 Virtualization |
Up to 4K clients (access switches and APs) virtualized into a single device |
Two layers of ASs allowed in an SVF system |
|
Third-party devices allowed between SVF parent and clients |
|
VLAN |
Access, trunk, and hybrid interface types, auto-negotiation of LNP links |
Default VLAN |
|
VLAN switching |
|
QinQ and selective QinQ |
|
MAC address-based VLAN assignment |
|
ARP |
256K ARP entries |
MAC Address |
1M MAC address entries |
Dynamic MAC address learning and aging |
|
Static, dynamic, and blackhole MAC address entries |
|
Source MAC address filtering |
|
MAC address limiting based on ports and VLANs |
|
Ring Network Protection |
Spanning Tree Protocol (STP) (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s) |
SEP |
|
Bridge Protocol Data Unit (BPDU), root protection, and loop protection |
|
BPDU tunnel |
|
G.8032 Ethernet Ring Protection Switching (ERPS) |
|
IP Routing |
3M IPv4 routing entries |
512K IPv6 routing entries |
|
IPv4 dynamic routing protocols, such as RIP, OSPF, IS-IS, and BGP |
|
IPv6 routing protocols, such as RIPng, OSPFv3, IS-ISv6, and BGP4+ |
|
Multicast |
128,000 multicast routing entries |
IGMP v1/v2/v3 and IGMP v1/v2/v3 snooping |
|
PIM-DM, PIM-SM, and PIM-SSM |
|
Multicast Source Discovery Protocol (MSDP) and Multiprotocol Extensions for BGP (MBGP) |
|
Fast leave |
|
Multicast traffic control |
|
Multicast querier |
|
Multicast protocol packet suppression |
|
Multicast Call Admission Control (CAC) |
|
Multicast ACL |
|
MPLS |
Basic MPLS functions |
MPLS Operations, Administration, and Maintenance (OAM) |
|
MPLS Traffic Engineering (TE) |
|
MPLS VPN/VLL/VPLS |
|
Reliability |
Link Aggregation Control Protocol (LACP) and E-Trunk |
Virtual Router Redundancy Protocol (VRRP) and Bi-directional Forwarding Detection (BFD) for VRRP |
|
BFD for BGP/IS-IS/OSPF/static route |
|
Non-Stop Routing (NSR), Non-Stop Forwarding (NSF) and Graceful Restart (GR) for BGP/IS-IS/OSPF/LDP |
|
TE Fast ReRoute (FRR) and IP FRR |
|
Eth-OAM 802.3ah and 802.1ag (hardware-based) |
|
HSR |
|
ITU-Y.1731 |
|
Device Link Detection Protocol (DLDP) |
|
QoS |
256K ACLs |
Traffic classification based on Layer 2 headers, Layer 3 protocols, Layer 4 protocols, and 802.1p priority |
|
ACLs and actions such as Committed Access Rate (CAR), re-marking, and scheduling |
|
Queuing algorithms, such as SP, WRR, DRR, SP + WRR, and SP + DRR |
|
Congestion avoidance mechanisms, including (WRED) and tail drop |
|
H-QoS |
|
Traffic shaping |
|
Network Synchronization |
Ethernet synchronization |
1588v2 |
|
Configuration and Maintenance |
Terminal access services such as console port login, Telnet, and SSH |
Network management protocols, such as SNMP v1/v2/v3 |
|
File uploading and downloading through FTP and TFTP |
|
BootROM upgrade and remote in-service upgrade |
|
Hot patches |
|
User operation logs |
|
Security and Management |
MAC address, Portal, 802.1x, and Dynamic Host Configuration Protocol (DHCP) snooping triggered authentication |
MACsec |
|
RADIUS and HWTACACS authentication for login users |
|
Command line authority control based on user levels, preventing unauthorized users from using command configurations |
|
Defense against DoS attacks, Transmission Control Protocol (TCP) SYN Flood attacks, User Datagram Protocol (UDP) Flood attacks, broadcast storms, and heavy traffic attacks |
|
Remote Network Monitoring (RMON) |
|
Security Protection* |
Firewall |
Network Address Translation (NAT) |
|
IPSec, SSL VPN |
|
Intrusion Protection System (IPS) |
|
Load balancing Analog Digital Conversion (ADC) |
|
Interoperability |
Interoperable with VBST (compatible with PVST/PVST+/RPVST) |
Interoperable with LNP (similar to DTP) |
|
Interoperable with VCMP (similar to VTP) |
|
Energy Saving |
Energy Efficient Ethernet (802.3az) |
Dimensions (H x W x D) |
841.75 mm x 442 mm x 489 mm, 19U |
Weight (empty chassis) |
63 kg |
Operating Voltage |
DC: –40V to –72V |
Maximum Power Consumption of the Entire Equipment |
≤ 6,600W |