Quick Quote ico
  • S5720-52X-EI-AC
  • S5720-52X-EI-AC

S5720-52X-EI-AC

Model:S5720-52X-EI-AC Huawei S5720 Series Switch
HuatenMax

Expertise Builds Trust

100+ Countries

6000+ Customers/Projects

CCIE, CISSP, JNCIE, NSE 7 AWS, Google Cloud Experts

Jim Huang

+86 136 9226 0946

Contact@huatenmax.com

Overview

Huawei S5720-52X-EI-AC switch, Next-Generation Enhanced Gigabit Switches, supports a large capacity of 2 GB SDRAM and 4 x 10GE uplink ports.

Quick Specs

Figure 1 shows the appearance of Huawei S5720-52X-EI-AC switch.

S5720-52X-EI-AC

Table 1 shows the Quick Specs.

Product Code

S5720-52X-EI-AC

Downlink Ports

48 x Ethernet 10/100/1000 ports

Uplink Ports

4 x 10G SFP+

Forwarding Performance

132 Mpps

Switching Capacity

598 Gbit/s

Stack

Supported

Stack connection mode

Service port connection, dedicated stack port connection (two QSFP+ stack ports on the rear panel)

SDRAM

2 GB

Flash Memory

340 MB

Power

Built-in AC power module, AC 110/220V

Heat Dissipation

Forced air cooling By Built-in fans

Installation mode

Rack mounting, desk mounting, wall mounting

300-mm deep cabinet

Not supported

Dimensions (W x D x H)

44.2 cm x 22 cm x 4.36 cm

Package Weight

5.57 Kg

Product Details

Figure 2 shows the front panel of Huawei S5720-52X-EI-AC switch.

S5720-52X-EI-AC Front Panel

Note:

Switch LEDs

One USB port

Mode Button

One console port

48 x 10/100/1000BASE-T

Ethernet electrical ports

One Mini USB port

4 x 10GE SFP+ Ethernet optical ports

One ETH management port

·Switch LEDs include PWR1, PWR2, SYS, STAT, SPED and STCK LEDs.

·One console port is used with a console cable. The console cable is not delivered with the switch and needs to be separately purchased if needed.

·4 x 10GE SFP+ Ethernet optical ports support GE, GE-CWDM, GE-DWDM, 10GE SFP+ and 10GE-CWDM optical module; GE copper module; 1 m, 3 m, 10 m SFP+ high-speed cables, 5 m SFP+ high-speed cables and 3 m, 10 m AOC cables.

Figure 3 shows the back panel of Huawei S5720-52X-EI-AC switch.

S5720-52X-EI-AC Back Panel

Note:

Ground screw

RPS socket

Two QSFP+ stack optical ports

AC power socket

·Ground screw is used with a ground cable.

·Two QSFP+ stack optical ports support QSFP+ optical modules.

·RPS socket is used with an RPS cable.

The Transceivers

Huawei S5720-52X-EI-AC switch supports many kinds of transceiver, such as 40GE optical transceivers, 10GE SFP+ optical transceivers, etc.

Table 2 shows the recommended 40GE optical transceivers.

Models

Description

QSFP-40G-iSR4

40GBase-iSR4 Optical Transceiver, QSFP+, 40G, Multi-mode (850nm, 0.15km, MPO) (Connect to four SFP+ Optical Transceiver)

Table 3 shows the recommended GE optical transceivers.

Models

Description

LE2MGSC40DE0

Optical Transceiver, eSFP, GE, BIDI Single-mode Module (TX1310/RX1490, 40km, LC)

LE2MGSC40ED0

Optical Transceiver, eSFP, GE, BIDI Single-mode Module (TX1490/RX1310, 40km, LC)

S-SFP-GE-LH40-SM1310

Optical Transceiver, eSFP, GE, Single-mode Module (1310nm, 40km, LC)

S-SFP-GE-LH40-SM1550

Optical Transceiver, eSFP, GE, Single-mode Module (1550nm, 40km, LC)

S-SFP-GE-LH80-SM1550

Optical Transceiver, eSFP, GE, Single-mode Module (1550nm, 80km, LC)

SFP-GE-BXU1-SC

1000Base,BIDI Optical Transceiver, SFP, GE, Single-mode Module (TX1490nm/RX1310nm, 10km, SC)

SFP-GE-LX-SM1310

Optical Transceiver, eSFP, GE, Single-mode Module (1310nm, 10km, LC)

SFP-GE-LX-SM1310-BIDI

Optical Transceiver, eSFP, GE, BIDI Single-mode Module (TX1310/RX1490, 10km, LC)

SFP-GE-LX-SM1490-BIDI

Optical Transceiver, eSFP, GE, BIDI Single-mode Module (TX1490/RX1310, 10km, LC)

SFP-GE-ZBXD1

Optical Transceiver, eSFP, GE, BIDI Single-mode Module (1570nm (Tx) / 1490nm (Rx), 80km, LC)

SFP-GE-ZBXU1

Optical Transceiver, eSFP, GE, BiDi Single-mode Module (1490nm (Tx) / 1570nm (Rx) ,80km, LC)

eSFP-GE-SX-MM850

Optical Transceiver, eSFP, GE, Multi-mode Module (850nm, 0.5km, LC)

eSFP-GE-ZX100-SM1550

Optical Transceiver, eSFP, GE, Single-mode Module (1550nm, 100km, LC)

Table 4 shows the recommended GE-CWDM optical transceivers.

Models

Description

CWDM-SFPGE-1491

CWDM Optical Transceiver, eSFP, 2.5G, Single-mode Module (1491nm, 80km, LC)

CWDM-SFPGE-1511

CWDM Optical Transceiver, eSFP, 2.5G, Single-mode Module (1511nm, 80km, LC)

CWDM-SFPGE-1531

CWDM Optical Transceiver, eSFP, 2.5G, Single-mode Module (1531nm, 80km, LC)

CWDM-SFPGE-1551

CWDM Optical Transceiver, eSFP, 2.5G, Single-mode Module (1551nm, 80km, LC)

Table 5 shows the recommended GE-DWDM optical transceivers.

Models

Description

DWDM-SFPGE-1542-14

DWDM Optical Transceiver, eSFP, 2.5G, Single-mode Module (1542.14nm, 120km, LC)

DWDM-SFPGE-1542-94

DWDM Optical Transceiver, eSFP, 2.5G, Single-mode Module (1542.94nm, 120km, LC)

DWDM-SFPGE-1543-73

DWDM Optical Transceiver, eSFP, 2.5G, Single-mode Module (1543.73nm, 120km, LC)

DWDM-SFPGE-1544-53

DWDM Optical Transceiver, eSFP, 2.5G, Single-mode Module (1544.53nm, 120km, LC)

Table 6 shows the recommended 10GE SFP+ optical transceivers.

Models

Description

OMXD30000

Optical Transceiver, SFP+, 10G, Multi-mode Module (850nm, 0.3km, LC)

OSX010000

Optical Transceiver, SFP+, 10G, Single-mode Module (1310nm, 10km, LC)

OSX040N01

Optical Transceiver, SFP+, 10G, Single-mode Module (1550nm, 40km, LC)

OSXD22N00

Optical Transceiver, SFP+, 10G, Multi-mode Module (1310nm, 0.22km, LC, LRM)

SFP-10G-BXD1

10GBase, BIDI Optical Transceiver, SFP+, 10G, Single-mode Module (TX1330nm / RX1270nm, 10km, LC)

SFP-10G-BXU1

10GBase, BIDI Optical Transceiver, SFP+, 10G, Single-mode Module (TX1270nm / RX1330nm, 10km, LC)

SFP-10G-USR

10GBase-USR Optical Transceiver, SFP+, 10G, Multi-mode Module (850nm, 0.1km, LC)

SFP-10G-ZR

10GBase-ZR Optical Transceiver, SFP+, 10G, Single-mode Module (1550nm, 80km, LC)

SFP-10G-iLR

Optical Transceiver, SFP+, 9.8G, Single-mode Module (1310nm, 1.4km, LC)

Table 7 shows the recommended 10GE-CWDM optical transceiver

Models

Description

SFP-10G-ZCW1471

Optical Transceiver, SFP+, 10G, Single-mode Module (CWDM, 1471nm, 70km, LC)

SFP-10G-ZCW1491

Optical Transceiver, SFP+, 10G, Single-mode Module (CWDM, 1491nm, 70km, LC)

SFP-10G-ZCW1511

Optical Transceiver, SFP+, 10G, Single-mode Module (CWDM, 1511nm, 70km, LC)

SFP-10G-ZCW1531

Optical Transceiver, SFP+, 10G, Single-mode Module (CWDM, 1531nm, 70km, LC)

SFP-10G-ZCW1551

Optical Transceiver, SFP+, 10G, Single-mode Module (CWDM, 1551nm, 70km, LC)

SFP-10G-ZCW1571

Optical Transceiver, SFP+, 10G, Single-mode Module (CWDM, 1571nm, 70km, LC)

SFP-10G-ZCW1591

Optical Transceiver, SFP+, 10G, Single-mode Module (CWDM, 1591nm, 70km, LC)

SFP-10G-ZCW1611

Optical Transceiver, SFP+, 10G, Single-mode Module (CWDM, 1611nm, 70km, LC)

Table 8 shows the recommended GE copper transceivers.

Models

Description

SFP-1000BaseT

Electrical Transceiver, SFP, GE, Electrical Interface Module (100m, RJ45)

Compare to Similar Items

Table 9 shows the comparison of Huawei?S5720-52X-EI-AC and S5720-52P-EI-AC switches.

Models

S5720-52X-EI-AC

S5720-52P-EI-AC

Downlink Ports

48 x 10/100/1,000 Base-T Ethernet ports

48 x 10/100/1,000 Base-T Ethernet ports

Uplink Ports

4 x 10G SFP+ ports

4 x 1,000 Base-X SFP ports

PoE Support

N/A

N/A

Power Supply

AC power supply, supporting RPS

AC power supply, supporting RPS

Get more information

Do you have any question about the Huawei S5720-52X-EI-AC switch

Contact us now via Live Chat or Contact@huatenmax.com.

Specification

S5720-52X-EI-AC Specification

Fixed Ports

48×10/100/1000Base-T, 4×10GE SFP+

MAC address table

IEEE 802.1d compliance

MAC address learning and aging

Static, dynamic, and blackhole MAC address entries

Packet filtering based on source MAC addresses

MAC address entries: 
S5700S-LI series: 8K, S5700-LI/S5700-SI series: 16K, S5700-EI series: 32K, S5720-EI series: 64K, S5700-HI series: S5700-HI: 32K, S5710-HI: 456K, S5720-HI: 128K

VLAN

4K VLANs

Guest VLAN and voice VLAN

GVRP

MUX VLAN

VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports

1:1 and N:1 VLAN Mapping

SuperVLAN(supported by the S5700-SI/S5700-EI/S5700-HI series)

Ring protection

RRPP ring topology and RRPP multi-instance

Smart Link tree topology and Smart Link multi-instance, providing the millisecond-level protection switchover

SEP

ERPS(G.8032)(supported by the S5700-LI/S5700-SI/S5700-EI/S5700-HI series)

STP, RSTP, and MSTP

BPDU protection, root protection, and loop protection

BPDU Tunnel

Reliability

Ethernet OAM (IEEE 802.3ah and 802.1ag)

ITU-Y.1731

DLDP

LACP

E-Trunk(supported by the S5700-SI/S5700-EI/S5700-HI series)

BFD for OSPF, BFD for IS-IS, BFD for VRRP, and BFD for PIM (supported by the S5700-EI/S5700-HI series)

MPLS features

MPLS L3VPN

MPLS L2VPN(VPWS/VPLS)

MPLS-TE

MPLS QoS

Notes: supported by S5710-EI, S5700-HI and S5710-HI

IP routing

Static routing

RIPv1, RIPv2 and RIPng,ECMP(supported by the S5700-SI/S5700-EI/S5700-HI series)

OSPF, OSPFv3, IS-IS, IS-ISv6, BGP and BGP4+ (supported by the S5700-EI/S5700-HI series)

IPv6 features

Neighbor Discovery (ND)

Path MTU (PMTU)

IPv6 ping, IPv6 tracert, and IPv6 Telnet

ACLs based on the source IPv6 address, destination IPv6 address, Layer 4 ports, or protocol type

MLD v1/v2 snooping

6to4 tunnel, ISATAP tunnel, and manually configured tunnel(supported by the S5700-SI/S5700-EI/S5700-HI series)

Multicast

IGMP v1/v2/v3 snooping and IGMP fast leave

Multicast forwarding in a VLAN and multicast replication between VLANs

Multicast load balancing among member ports of a trunk

Controllable multicast

Port-based multicast traffic statistics

IGMP v1/v2/v3, PIM-SM, PIM-DM, PIM-SSM, MSDP (supported by the S5700-EI/S5700-HI series)

QoS/ACL

Rate limiting on packets sent and received by an interface

Packet redirection

Port-based traffic policing and two-rate three-color CAR

Eight queues on each port

WRR, DRR, SP, WRR+SP, and DRR+SP queue scheduling algorithms

WRED (supported by the S5710-EI and S5700-HI)

Re-marking of the 802.1p priority and DSCP priority

Packet filtering at Layers 2 through 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, TCP/UDP port number, protocol type, and VLAN ID

Rate limiting in each queue and traffic shaping on ports

Security

User privilege management and password protection

DoS attack defense, ARP attack defense, and ICMP attack defense

Binding of the IP address, MAC address, interface, and VLAN

Port isolation, port security, and sticky MAC

MFF

Blackhole MAC address entries

Limit on the number of learned MAC addresses

802.1x authentication and limit on the number of users on an interface

AAA authentication, RADIUS authentication, HWTACACS authentication, and NAC

SSH v2.0

Hypertext Transfer Protocol Secure (HTTPS)

CPU defense

Blacklist and whitelist

Access Security

DHCP Relay, DHCP Server, DHCP Snooping, DHCP Security

Management and maintenance

Virtual cable test

Port mirroring and RSPAN (remote port mirroring)

Remote configuration and maintenance using Telnet

SNMP v1/v2c/v3

RMON

Web NMS

HGMP

System logs and alarms of different levels

802.3az EEE (supported by the S5700(S)-LI, S5710-EI, S5700-HI and S5710-HI)

Dying gasp (supported by the S5700-HI, S5710-HI and S5700(S)-LI(except battery LAN switches)

NetStream (supported by the S5710-EI, S5700-HI and S5710-HI)

sFlow(supported by the S5700(S)-LI/S5700-EI/S5700-HI series)

Interoperability

Supports VBST (Compatible with PVST/PVST+/RPVST)

Supports LNP (Similar to DTP)

Supports VCMP (Similar to VTP)

Operating environment

Operating temperature: 0℃–50℃

Relative humidity: 10%–90% (non-condensing)

Input voltage

AC:

Rated voltage range: 100 V to 240 V AC, 50/60 Hz

Maximum voltage range: 90 V to 264 V AC, 47/63 Hz

Dimensions (W x D x H)

44.2 cm x 22 cm x 4.36 cm

Powerconsumption

S5720-52X-EI-AC <61.5W

Products Tags

Follow us and the future of network

Follow us, you will get the latest products and industry information in our insights emails.
Subscribe now also can get more than 50 valuable white papers. Learn Details>>>