Huawei S5720-52X-EI-AC switch, Next-Generation Enhanced Gigabit Switches, supports a large capacity of 2 GB SDRAM and 4 x 10GE uplink ports.
Figure 1 shows the appearance of Huawei S5720-52X-EI-AC switch.
Table 1 shows the Quick Specs.
Product Code |
|
Downlink Ports |
48 x Ethernet 10/100/1000 ports |
Uplink Ports |
4 x 10G SFP+ |
Forwarding Performance |
132 Mpps |
Switching Capacity |
598 Gbit/s |
Stack |
Supported |
Stack connection mode |
Service port connection, dedicated stack port connection (two QSFP+ stack ports on the rear panel) |
SDRAM |
2 GB |
Flash Memory |
340 MB |
Power |
Built-in AC power module, AC 110/220V |
Heat Dissipation |
Forced air cooling By Built-in fans |
Installation mode |
Rack mounting, desk mounting, wall mounting |
300-mm deep cabinet |
Not supported |
Dimensions (W x D x H) |
44.2 cm x 22 cm x 4.36 cm |
Package Weight |
5.57 Kg |
Figure 2 shows the front panel of Huawei S5720-52X-EI-AC switch.
Note:
① |
Switch LEDs |
⑤ |
One USB port |
② |
Mode Button |
⑥ |
One console port |
③ |
48 x 10/100/1000BASE-T Ethernet electrical ports |
⑦ |
One Mini USB port |
④ |
4 x 10GE SFP+ Ethernet optical ports |
⑧ |
One ETH management port |
·Switch LEDs include PWR1, PWR2, SYS, STAT, SPED and STCK LEDs.
·One console port is used with a console cable. The console cable is not delivered with the switch and needs to be separately purchased if needed.
·4 x 10GE SFP+ Ethernet optical ports support GE, GE-CWDM, GE-DWDM, 10GE SFP+ and 10GE-CWDM optical module; GE copper module; 1 m, 3 m, 10 m SFP+ high-speed cables, 5 m SFP+ high-speed cables and 3 m, 10 m AOC cables.
Figure 3 shows the back panel of Huawei S5720-52X-EI-AC switch.
Note:
① |
Ground screw |
③ |
RPS socket |
② |
Two QSFP+ stack optical ports |
④ |
AC power socket |
·Ground screw is used with a ground cable.
·Two QSFP+ stack optical ports support QSFP+ optical modules.
·RPS socket is used with an RPS cable.
Huawei S5720-52X-EI-AC switch supports many kinds of transceiver, such as 40GE optical transceivers, 10GE SFP+ optical transceivers, etc.
Table 2 shows the recommended 40GE optical transceivers.
Models |
Description |
40GBase-iSR4 Optical Transceiver, QSFP+, 40G, Multi-mode (850nm, 0.15km, MPO) (Connect to four SFP+ Optical Transceiver) |
Table 3 shows the recommended GE optical transceivers.
Models |
Description |
Optical Transceiver, eSFP, GE, BIDI Single-mode Module (TX1310/RX1490, 40km, LC) |
|
Optical Transceiver, eSFP, GE, BIDI Single-mode Module (TX1490/RX1310, 40km, LC) |
|
Optical Transceiver, eSFP, GE, Single-mode Module (1310nm, 40km, LC) |
|
Optical Transceiver, eSFP, GE, Single-mode Module (1550nm, 40km, LC) |
|
Optical Transceiver, eSFP, GE, Single-mode Module (1550nm, 80km, LC) |
|
1000Base,BIDI Optical Transceiver, SFP, GE, Single-mode Module (TX1490nm/RX1310nm, 10km, SC) |
|
Optical Transceiver, eSFP, GE, Single-mode Module (1310nm, 10km, LC) |
|
Optical Transceiver, eSFP, GE, BIDI Single-mode Module (TX1310/RX1490, 10km, LC) |
|
Optical Transceiver, eSFP, GE, BIDI Single-mode Module (TX1490/RX1310, 10km, LC) |
|
Optical Transceiver, eSFP, GE, BIDI Single-mode Module (1570nm (Tx) / 1490nm (Rx), 80km, LC) |
|
Optical Transceiver, eSFP, GE, BiDi Single-mode Module (1490nm (Tx) / 1570nm (Rx) ,80km, LC) |
|
Optical Transceiver, eSFP, GE, Multi-mode Module (850nm, 0.5km, LC) |
|
Optical Transceiver, eSFP, GE, Single-mode Module (1550nm, 100km, LC) |
Table 4 shows the recommended GE-CWDM optical transceivers.
Models |
Description |
CWDM Optical Transceiver, eSFP, 2.5G, Single-mode Module (1491nm, 80km, LC) |
|
CWDM Optical Transceiver, eSFP, 2.5G, Single-mode Module (1511nm, 80km, LC) |
|
CWDM Optical Transceiver, eSFP, 2.5G, Single-mode Module (1531nm, 80km, LC) |
|
CWDM Optical Transceiver, eSFP, 2.5G, Single-mode Module (1551nm, 80km, LC) |
Table 5 shows the recommended GE-DWDM optical transceivers.
Models |
Description |
DWDM Optical Transceiver, eSFP, 2.5G, Single-mode Module (1542.14nm, 120km, LC) |
|
DWDM Optical Transceiver, eSFP, 2.5G, Single-mode Module (1542.94nm, 120km, LC) |
|
DWDM Optical Transceiver, eSFP, 2.5G, Single-mode Module (1543.73nm, 120km, LC) |
|
DWDM Optical Transceiver, eSFP, 2.5G, Single-mode Module (1544.53nm, 120km, LC) |
Table 6 shows the recommended 10GE SFP+ optical transceivers.
Models |
Description |
Optical Transceiver, SFP+, 10G, Multi-mode Module (850nm, 0.3km, LC) |
|
Optical Transceiver, SFP+, 10G, Single-mode Module (1310nm, 10km, LC) |
|
Optical Transceiver, SFP+, 10G, Single-mode Module (1550nm, 40km, LC) |
|
Optical Transceiver, SFP+, 10G, Multi-mode Module (1310nm, 0.22km, LC, LRM) |
|
10GBase, BIDI Optical Transceiver, SFP+, 10G, Single-mode Module (TX1330nm / RX1270nm, 10km, LC) |
|
10GBase, BIDI Optical Transceiver, SFP+, 10G, Single-mode Module (TX1270nm / RX1330nm, 10km, LC) |
|
10GBase-USR Optical Transceiver, SFP+, 10G, Multi-mode Module (850nm, 0.1km, LC) |
|
10GBase-ZR Optical Transceiver, SFP+, 10G, Single-mode Module (1550nm, 80km, LC) |
|
Optical Transceiver, SFP+, 9.8G, Single-mode Module (1310nm, 1.4km, LC) |
Table 7 shows the recommended 10GE-CWDM optical transceiver
Models |
Description |
Optical Transceiver, SFP+, 10G, Single-mode Module (CWDM, 1471nm, 70km, LC) |
|
Optical Transceiver, SFP+, 10G, Single-mode Module (CWDM, 1491nm, 70km, LC) |
|
Optical Transceiver, SFP+, 10G, Single-mode Module (CWDM, 1511nm, 70km, LC) |
|
Optical Transceiver, SFP+, 10G, Single-mode Module (CWDM, 1531nm, 70km, LC) |
|
Optical Transceiver, SFP+, 10G, Single-mode Module (CWDM, 1551nm, 70km, LC) |
|
Optical Transceiver, SFP+, 10G, Single-mode Module (CWDM, 1571nm, 70km, LC) |
|
Optical Transceiver, SFP+, 10G, Single-mode Module (CWDM, 1591nm, 70km, LC) |
|
Optical Transceiver, SFP+, 10G, Single-mode Module (CWDM, 1611nm, 70km, LC) |
Table 8 shows the recommended GE copper transceivers.
Models |
Description |
Electrical Transceiver, SFP, GE, Electrical Interface Module (100m, RJ45) |
Table 9 shows the comparison of Huawei?S5720-52X-EI-AC and S5720-52P-EI-AC switches.
Models |
||
Downlink Ports |
48 x 10/100/1,000 Base-T Ethernet ports |
48 x 10/100/1,000 Base-T Ethernet ports |
Uplink Ports |
4 x 10G SFP+ ports |
4 x 1,000 Base-X SFP ports |
PoE Support |
N/A |
N/A |
Power Supply |
AC power supply, supporting RPS |
AC power supply, supporting RPS |
Do you have any question about the Huawei S5720-52X-EI-AC switch
Contact us now via Live Chat or Contact@huatenmax.com.
S5720-52X-EI-AC Specification |
|
Fixed Ports |
48×10/100/1000Base-T, 4×10GE SFP+ |
MAC address table |
IEEE 802.1d compliance |
MAC address learning and aging |
|
Static, dynamic, and blackhole MAC address entries |
|
Packet filtering based on source MAC addresses |
|
MAC address entries: |
|
VLAN |
4K VLANs |
Guest VLAN and voice VLAN |
|
GVRP |
|
MUX VLAN |
|
VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports |
|
1:1 and N:1 VLAN Mapping |
|
SuperVLAN(supported by the S5700-SI/S5700-EI/S5700-HI series) |
|
Ring protection |
RRPP ring topology and RRPP multi-instance |
Smart Link tree topology and Smart Link multi-instance, providing the millisecond-level protection switchover |
|
SEP |
|
ERPS(G.8032)(supported by the S5700-LI/S5700-SI/S5700-EI/S5700-HI series) |
|
STP, RSTP, and MSTP |
|
BPDU protection, root protection, and loop protection |
|
BPDU Tunnel |
|
Reliability |
Ethernet OAM (IEEE 802.3ah and 802.1ag) |
ITU-Y.1731 |
|
DLDP |
|
LACP |
|
E-Trunk(supported by the S5700-SI/S5700-EI/S5700-HI series) |
|
BFD for OSPF, BFD for IS-IS, BFD for VRRP, and BFD for PIM (supported by the S5700-EI/S5700-HI series) |
|
MPLS features |
MPLS L3VPN |
MPLS L2VPN(VPWS/VPLS) |
|
MPLS-TE |
|
MPLS QoS |
|
Notes: supported by S5710-EI, S5700-HI and S5710-HI |
|
IP routing |
Static routing |
RIPv1, RIPv2 and RIPng,ECMP(supported by the S5700-SI/S5700-EI/S5700-HI series) |
|
OSPF, OSPFv3, IS-IS, IS-ISv6, BGP and BGP4+ (supported by the S5700-EI/S5700-HI series) |
|
IPv6 features |
Neighbor Discovery (ND) |
Path MTU (PMTU) |
|
IPv6 ping, IPv6 tracert, and IPv6 Telnet |
|
ACLs based on the source IPv6 address, destination IPv6 address, Layer 4 ports, or protocol type |
|
MLD v1/v2 snooping |
|
6to4 tunnel, ISATAP tunnel, and manually configured tunnel(supported by the S5700-SI/S5700-EI/S5700-HI series) |
|
Multicast |
IGMP v1/v2/v3 snooping and IGMP fast leave |
Multicast forwarding in a VLAN and multicast replication between VLANs |
|
Multicast load balancing among member ports of a trunk |
|
Controllable multicast |
|
Port-based multicast traffic statistics |
|
IGMP v1/v2/v3, PIM-SM, PIM-DM, PIM-SSM, MSDP (supported by the S5700-EI/S5700-HI series) |
|
QoS/ACL |
Rate limiting on packets sent and received by an interface |
Packet redirection |
|
Port-based traffic policing and two-rate three-color CAR |
|
Eight queues on each port |
|
WRR, DRR, SP, WRR+SP, and DRR+SP queue scheduling algorithms |
|
WRED (supported by the S5710-EI and S5700-HI) |
|
Re-marking of the 802.1p priority and DSCP priority |
|
Packet filtering at Layers 2 through 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, TCP/UDP port number, protocol type, and VLAN ID |
|
Rate limiting in each queue and traffic shaping on ports |
|
Security |
User privilege management and password protection |
DoS attack defense, ARP attack defense, and ICMP attack defense |
|
Binding of the IP address, MAC address, interface, and VLAN |
|
Port isolation, port security, and sticky MAC |
|
MFF |
|
Blackhole MAC address entries |
|
Limit on the number of learned MAC addresses |
|
802.1x authentication and limit on the number of users on an interface |
|
AAA authentication, RADIUS authentication, HWTACACS authentication, and NAC |
|
SSH v2.0 |
|
Hypertext Transfer Protocol Secure (HTTPS) |
|
CPU defense |
|
Blacklist and whitelist |
|
Access Security |
DHCP Relay, DHCP Server, DHCP Snooping, DHCP Security |
Management and maintenance |
Virtual cable test |
Port mirroring and RSPAN (remote port mirroring) |
|
Remote configuration and maintenance using Telnet |
|
SNMP v1/v2c/v3 |
|
RMON |
|
Web NMS |
|
HGMP |
|
System logs and alarms of different levels |
|
802.3az EEE (supported by the S5700(S)-LI, S5710-EI, S5700-HI and S5710-HI) |
|
Dying gasp (supported by the S5700-HI, S5710-HI and S5700(S)-LI(except battery LAN switches) |
|
NetStream (supported by the S5710-EI, S5700-HI and S5710-HI) |
|
sFlow(supported by the S5700(S)-LI/S5700-EI/S5700-HI series) |
|
Interoperability |
Supports VBST (Compatible with PVST/PVST+/RPVST) |
Supports LNP (Similar to DTP) |
|
Supports VCMP (Similar to VTP) |
|
Operating environment |
Operating temperature: 0℃–50℃ |
Relative humidity: 10%–90% (non-condensing) |
|
Input voltage |
AC: Rated voltage range: 100 V to 240 V AC, 50/60 Hz Maximum voltage range: 90 V to 264 V AC, 47/63 Hz |
Dimensions (W x D x H) |
44.2 cm x 22 cm x 4.36 cm |
Powerconsumption |
S5720-52X-EI-AC <61.5W |