The S5700-52X-LI-48CS-AC gigabit enterprise switch is next-generation energy-saving switch developed by Huawei. With forty-eight GE CSFP ports, four Combo 10/100/1,000 Base-T Ethernet ports, and four 10 GE SFP+ ports, it provides a large switching capacity and high-density GE ports to implement quick upstream transmissions, widely used in various application scenarios like enterprise park access, convergence, gigabit access of data center application scenarios. CSFP switches support downlink CSFP ports, and each downlink CSFP port provides bi-directional 2 Gbit/s bandwidth. Using advanced energy conservation technology, the S5700-52X-LI-48CS-AC is dedicated to helping enterprise customers build a reliable and secure next-generation IT network.
Figure 1 shows the appearance of Huawei S5700-52X-LI-48CS-AC.
Table 1 shows the Quick Specs.
Product Code |
|
Fixed Ports |
48 x GE CSFP ports or 24 x GE SFP ports, 4 x Combo 10/100/1,000 Base-T Ethernet ports, 4 x 10 GE SFP+ ports |
MAC Address Table Size |
16 MAC |
Voltage Required |
AC Rated voltage range: 100V to 240V AC, 50/60 Hz Maximum voltage range: 90V to 264V AC, 47/63 Hz |
Power Device |
AC power supply, supporting RPS |
Power Consumption Operational |
< 79.9W |
Forwarding Performance |
132 Mpps |
Switching Capacity |
256 Gbit/s |
Memory (RAM) |
256 MB |
Flash |
200MB |
Dimensions (W x D x H) |
442 mm x 220 mm x 43.6 mm |
Weight |
4.5 kg |
Figure 2 shows the front panel of Huawei S5700-52X-LI-48CS-AC.
Note:
① |
Forty-four 100/1000BASE-X CSFP ports |
② |
Four combo ports (10/100/1000BASE-T + 100/1000BASE-X) |
③ |
Four 10GE SFP+ ports |
④ |
One mini USB port |
⑤ |
One console port |
⑥ |
One USB port |
⑦ |
AC socket |
⑧ |
Jack for AC terminal locking latch |
*When all the ports have CSFP optical modules installed, each port functions as two ports. The switch has a total of 44 ports in this case.
*When all the ports have SFP optical modules installed, each port functions as one port. The switch has a total of 22 ports.
*The four combo ports (numbered 45, 46, 47, and 48) on a CSFP switch include four electrical ports and two optical ports. The two optical ports can function as four optical modules when they have Compact Small Form-Factor Pluggable (CSFP) optical modules installed. When the two optical ports have SFP optical modules installed, the electrical ports 45 and 48 can be used normally.
*AC socket is used with an AC power cable.
*The AC terminal locking latch is not delivered with the switch.
Figure 3 shows the back panel of Huawei S5700-52X-LI-48CS-AC.
Note:
① |
Ground screw |
② |
RPS socket |
*The ground screw is used with a ground cable.
*RPS socket is used with an RPS cable, which is not hot swappable.
Table 2 shows the recommended modules.
Category |
Model |
Description |
FE-SFP Optical Transceiver |
Optical Transceiver,SFP,100M/155M,Multi-mode Module(1310nm,2km,LC) |
|
Optical Transceiver,eSFP,100M/155M,Single-mode Module(1310nm,15km,LC) |
||
10G-SFP+ Optical Transceiver |
Optical Transceiver,SFP+,10G,Single-mode Module(1310nm,10km,LC) |
|
Optical Transceiver,SFP+,10G,Multi-mode Module(850nm,0.3km,LC) |
||
GE Optical Transceiver |
Optical Transceiver, eSFP, GE, Multi-mode Module(850nm,0.55km,LC) |
|
Optical Transceiver, eSFP, GE, Single-mode Module(1310nm,10km,LC) |
||
Optical Transceiver, eSFP, GE, Single-mode Module(1310nm,40km,LC) |
||
Optical Transceiver, eSFP, GE, Single-mode Module(1550nm,40km,LC) |
||
GE Copper Transceiver |
Electrical Transceiver, SFP, GE, Electrical Interface Module(100m,RJ45) |
|
CSFP Optical Transceiver |
100/1000BASE-BIDI CSFP Optical Transceiver, CSFP,GE/FE, Single-mode Module(Tx1490/Rx1310nm,10km,LC) |
|
100/1000BASE-BX CSFP Optical Transceiver, CSFP, GE/FE, Single-mode Module(Tx1490/Rx1310nm,40km,LC) |
Table 3 shows the comparison of HuaweiS5700-52P-LI-AC, S5700-52X-LI-AC and S5700-52X-LI-48CS-AC.
Models |
|||
Fixed Ports |
48 x 10/100/1,000 Base-T Ethernet ports, 4 x GE SFP ports |
48 x 10/100/1,000 Base-T Ethernet ports, 4 x 10 GE SFP+ ports |
48 x GE CSFP ports or 24 x GE SFP ports, 4 x Combo10/100/1,000 Base-T Ethernet ports, 4 x 10 GE SFP+ ports |
Power Supply |
AC |
AC |
AC |
PoE |
Not supported |
Not supported |
Not supported |
Forwarding Performance |
78 Mpps |
132 Mpps |
132 Mpps |
Switching Capacity |
256 Gbit/s |
256 Gbit/s |
256 Gbit/s |
Power Consumption |
< 48.4W |
< 61W |
< 79.9W |
Do you have any question about the Huawei S5700-52X-LI-48CS-AC switch?
Contact us now via Live Chat or Contact@huatenmax.com.
S5700-52X-LI-48CS-AC Specification |
|
Fixed port |
48x1000Base-X(CSFP) or 24 × 1000Base-X, 4 of which are dual-purpose 10/100/1000 or Base-X(CSFP), 4 × 10GE SFP+ |
MAC address table |
IEEE 802.1d compliance MAC address learning and aging Static, dynamic, and blackhole MAC address entries Packet filtering based on source MAC addresses MAC address entries: 16K |
VLAN |
4K VLANs Guest VLAN and voice VLAN GVRP MUX VLAN VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports 1:1 and N:1 VLAN Mapping |
Ring protection |
RRPP ring topology and RRPP multi-instance Smart Link tree topology and Smart Link multi-instance, providing the millisecond-level protection switchover SEP ERPS(G.8032)(supported by the S5700-LI/S5700-SI/S5700-EI/S5700-HI series) STP, RSTP, and MSTP BPDU protection, root protection, and loop protection BPDU Tunnel |
Reliability |
Ethernet OAM (IEEE 802.3ah and 802.1ag) ITU-Y.1731 DLDP LACP |
MPLS features |
MPLS L3VPN MPLS L2VPN(VPWS/VPLS) MPLS-TE MPLS QoS |
IP routing |
Static routing |
IPv6 features |
Neighbor Discovery (ND) Path MTU (PMTU) IPv6 ping, IPv6 tracert, and IPv6 Telnet ACLs based on the source IPv6 address, destination IPv6 address, Layer 4 ports, or protocol type MLD v1/v2 snooping |
Multicast |
IGMP v1/v2/v3 snooping and IGMP fast leave Multicast forwarding in a VLAN and multicast replication between VLANs Multicast load balancing among member ports of a trunk Controllable multicast Port-based multicast traffic statistics |
QoS/ACL |
Rate limiting on packets sent and received by an interface Packet redirection Port-based traffic policing and two-rate three-color CAR Eight queues on each port WRR, DRR, SP, WRR+SP, and DRR+SP queue scheduling algorithms Re-marking of the 802.1p priority and DSCP priority Packet filtering at Layers 2 through 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, TCP/UDP port number, protocol type, and VLAN ID Rate limiting in each queue and traffic shaping on ports |
Security |
User privilege management and password protection DoS attack defense, ARP attack defense, and ICMP attack defense Binding of the IP address, MAC address, interface, and VLAN Port isolation, port security, and sticky MAC MFF Blackhole MAC address entries Limit on the number of learned MAC addresses 802.1x authentication and limit on the number of users on an interface AAA authentication, RADIUS authentication, HWTACACS authentication, and NAC SSH v2.0 Hypertext Transfer Protocol Secure (HTTPS) CPU defense Blacklist and whitelist |
Access Security |
DHCP Relay, DHCP Server, DHCP Snooping, DHCP Security |
Management and maintenance |
Virtual cable test Port mirroring and RSPAN (remote port mirroring) Remote configuration and maintenance using Telnet SNMP v1/v2c/v3 RMON Web NMS HGMP System logs and alarms of different levels 802.3az EEE Dying gasp sFlow |
Interoperability |
Supports VBST (Compatible with PVST/PVST+/RPVST) Supports LNP (Similar to DTP) Supports VCMP (Similar to VTP) |
Operating environment |
Operating temperature: 0℃–50℃ Relative humidity: 10%–90% (non-condensing) |
Input voltage |
AC: -Rated voltage range: 100 V to 240 V AC, 50/60 Hz -Maximum voltage range: 90 V to 264 V AC, 47/63 Hz |
Dimensions (W x D x H) |
442 x 220 x 43.6 mm |
Powerconsumption |
<79.9W |