The S5700-52X-LI-48CS-AC gigabit enterprise switch is next-generation energy-saving switch developed by Huawei. With forty-eight GE CSFP ports, four Combo 10/100/1,000 Base-T Ethernet ports, and four 10 GE SFP+ ports, it provides a large switching capacity and high-density GE ports to implement quick upstream transmissions, widely used in various application scenarios like enterprise park access, convergence, gigabit access of data center application scenarios. CSFP switches support downlink CSFP ports, and each downlink CSFP port provides bi-directional 2 Gbit/s bandwidth. Using advanced energy conservation technology, the S5700-52X-LI-48CS-AC is dedicated to helping enterprise customers build a reliable and secure next-generation IT network.

Quick Specs

Figure 1 shows the appearance of Huawei S5700-52X-LI-48CS-AC.

S5700-52X-LI-48CS-AC

Table 1 shows the Quick Specs.

Product Code

S5700-52X-LI-48CS-AC

Fixed Ports

48 x GE CSFP ports or 24 x GE SFP ports,

4 x Combo 10/100/1,000 Base-T Ethernet ports,

4 x 10 GE SFP+ ports

MAC Address Table Size

16 MAC

Voltage Required

AC

Rated voltage range: 100V to 240V AC, 50/60 Hz

Maximum voltage range: 90V to 264V AC, 47/63 Hz

Power Device

AC power supply, supporting RPS

Power Consumption Operational

< 79.9W

Forwarding Performance

132 Mpps

Switching Capacity

256 Gbit/s 

Memory (RAM)

256 MB

Flash

 200MB

Dimensions (W x D x H)

442 mm x 220 mm x 43.6 mm

Weight

4.5 kg

Product Details

Figure 2 shows the front panel of Huawei S5700-52X-LI-48CS-AC.

S5700-52X-LI-48CS-AC front

 Note:

Forty-four 100/1000BASE-X CSFP ports

Four combo ports (10/100/1000BASE-T + 100/1000BASE-X)

Four 10GE SFP+ ports

One mini USB port

One console port

One USB port

AC socket

Jack for AC terminal locking latch

*When all the ports have CSFP optical modules installed, each port functions as two ports. The switch has a total of 44 ports in this case.

*When all the ports have SFP optical modules installed, each port functions as one port. The switch has a total of 22 ports.

*The four combo ports (numbered 45, 46, 47, and 48) on a CSFP switch include four electrical ports and two optical ports. The two optical ports can function as four optical modules when they have Compact Small Form-Factor Pluggable (CSFP) optical modules installed. When the two optical ports have SFP optical modules installed, the electrical ports 45 and 48 can be used normally.

*AC socket is used with an AC power cable.

*The AC terminal locking latch is not delivered with the switch.

Figure 3 shows the back panel of Huawei S5700-52X-LI-48CS-AC.

S5700-52X-LI-48CS-AC back

 Note:

Ground screw

RPS socket

*The ground screw is used with a ground cable.

*RPS socket is used with an RPS cable, which is not hot swappable.

Recommended Modules

Table 2 shows the recommended modules.

Category

Model

Description

FE-SFP Optical Transceiver

SFP-FE-SX-MM1310

Optical Transceiver,SFP,100M/155M,Multi-mode Module(1310nm,2km,LC)

eSFP-FE-LX-SM1310

Optical Transceiver,eSFP,100M/155M,Single-mode Module(1310nm,15km,LC)

10G-SFP+ Optical

Transceiver

OSX010000

Optical Transceiver,SFP+,10G,Single-mode Module(1310nm,10km,LC)

OMXD30000

Optical Transceiver,SFP+,10G,Multi-mode Module(850nm,0.3km,LC)

GE Optical

Transceiver

eSFP-GE-SX-MM850

Optical Transceiver, eSFP, GE, Multi-mode Module(850nm,0.55km,LC)

SFP-GE-LX-SM1310

Optical Transceiver, eSFP, GE, Single-mode Module(1310nm,10km,LC)

S-SFP-GE-LH40-SM1310

Optical Transceiver, eSFP, GE, Single-mode Module(1310nm,40km,LC)

S-SFP-GE-LH40-SM1550

Optical Transceiver, eSFP, GE, Single-mode Module(1550nm,40km,LC)

GE Copper

Transceiver

SFP-1000BaseT

Electrical Transceiver, SFP, GE, Electrical Interface Module(100m,RJ45)

CSFP Optical

Transceiver

CSFP-GE-FE-BXD1

100/1000BASE-BIDI CSFP Optical Transceiver, CSFP,GE/FE, Single-mode

Module(Tx1490/Rx1310nm,10km,LC)

CSFP-GE-FE-BIDI4

100/1000BASE-BX CSFP Optical Transceiver, CSFP, GE/FE, Single-mode

Module(Tx1490/Rx1310nm,40km,LC)

Compare with Similar Item       

Table 3 shows the comparison of HuaweiS5700-52P-LI-AC, S5700-52X-LI-AC and S5700-52X-LI-48CS-AC.

Models

S5700-52P-LI-AC

S5700-52X-LI-AC

S5700-52X-LI-48CS-AC

Fixed Ports

48 x 10/100/1,000 Base-T Ethernet ports, 4 x GE SFP ports

48 x 10/100/1,000 Base-T Ethernet ports, 4 x 10 GE SFP+ ports

48 x GE CSFP ports or 24 x GE SFP ports, 4 x Combo10/100/1,000 Base-T Ethernet ports, 4 x 10 GE SFP+ ports

Power Supply

AC

AC

AC

PoE

Not supported

Not supported

Not supported

Forwarding Performance

78 Mpps

132 Mpps

132 Mpps

Switching Capacity

256 Gbit/s 

256 Gbit/s

256 Gbit/s

Power Consumption

< 48.4W

< 61W

< 79.9W

Get more information

Do you have any question about the Huawei S5700-52X-LI-48CS-AC switch?

Contact us now via Live Chat or Contact@huatenmax.com.

Specification

 

S5700-52X-LI-48CS-AC Specification 

Fixed port

48x1000Base-X(CSFP) or 24 × 1000Base-X, 4 of which are dual-purpose 10/100/1000 or Base-X(CSFP), 4 × 10GE SFP+

MAC address table

IEEE 802.1d compliance

MAC address learning and aging

Static, dynamic, and blackhole MAC address entries

Packet filtering based on source MAC addresses

MAC address entries: 16K

VLAN

4K VLANs

Guest VLAN and voice VLAN

GVRP

MUX VLAN

VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports

1:1 and N:1 VLAN Mapping

Ring protection

RRPP ring topology and RRPP multi-instance

Smart Link tree topology and Smart Link multi-instance, providing the millisecond-level protection switchover

SEP

ERPS(G.8032)(supported by the S5700-LI/S5700-SI/S5700-EI/S5700-HI series)

STP, RSTP, and MSTP

BPDU protection, root protection, and loop protection

BPDU Tunnel

Reliability

Ethernet OAM (IEEE 802.3ah and 802.1ag)

ITU-Y.1731

DLDP

LACP

MPLS features

MPLS L3VPN

MPLS L2VPN(VPWS/VPLS)

MPLS-TE

MPLS QoS

IP routing

Static routing

IPv6 features

Neighbor Discovery (ND)

Path MTU (PMTU)

IPv6 ping, IPv6 tracert, and IPv6 Telnet

ACLs based on the source IPv6 address, destination IPv6 address, Layer 4 ports, or protocol type

MLD v1/v2 snooping

Multicast

IGMP v1/v2/v3 snooping and IGMP fast leave

Multicast forwarding in a VLAN and multicast replication between VLANs

Multicast load balancing among member ports of a trunk

Controllable multicast

Port-based multicast traffic statistics

QoS/ACL

Rate limiting on packets sent and received by an interface

Packet redirection

Port-based traffic policing and two-rate three-color CAR

Eight queues on each port

WRR, DRR, SP, WRR+SP, and DRR+SP queue scheduling algorithms

Re-marking of the 802.1p priority and DSCP priority

Packet filtering at Layers 2 through 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, TCP/UDP port number, protocol type, and VLAN ID

Rate limiting in each queue and traffic shaping on ports

Security

User privilege management and password protection

DoS attack defense, ARP attack defense, and ICMP attack defense

Binding of the IP address, MAC address, interface, and VLAN

Port isolation, port security, and sticky MAC

MFF

Blackhole MAC address entries

Limit on the number of learned MAC addresses

802.1x authentication and limit on the number of users on an interface

AAA authentication, RADIUS authentication, HWTACACS authentication, and NAC

SSH v2.0

Hypertext Transfer Protocol Secure (HTTPS)

CPU defense

Blacklist and whitelist

Access Security

DHCP Relay, DHCP Server, DHCP Snooping, DHCP Security

Management and maintenance

Virtual cable test

Port mirroring and RSPAN (remote port mirroring)

Remote configuration and maintenance using Telnet

SNMP v1/v2c/v3

RMON

Web NMS

HGMP

System logs and alarms of different levels

802.3az EEE

Dying gasp

sFlow

Interoperability

Supports VBST (Compatible with PVST/PVST+/RPVST)

Supports LNP (Similar to DTP)

Supports VCMP (Similar to VTP)

Operating environment

Operating temperature: 0℃–50℃

Relative humidity: 10%–90% (non-condensing)

Input voltage

AC:

-Rated voltage range: 100 V to 240 V AC, 50/60 Hz

-Maximum voltage range: 90 V to 264 V AC, 47/63 Hz

Dimensions (W x D x H)

442 x 220 x 43.6 mm

Powerconsumption

<79.9W