Quick Quote ico
  • Huawei RH 1288A V2 server
  • Huawei RH 1288A V2 server

Huawei RH 1288A V2 server

Model:
HuatenMax

Expertise Builds Trust

100+ Countries

6000+ Customers/Projects

CCIE, CISSP, JNCIE, NSE 7 AWS, Google Cloud Experts

Jim Huang

+86 136 9226 0946

Contact@huatenmax.com

Overview

Huawei RH1288A V2 rack server is designed for compute intensive and cloud applications. This high-performance 1U rack server supports 2 Intel Xeon E5-2600 V2 series processors, 8*DDR3 RDIMMs/LRDIMMS slots, 8*2.5” SAS/SATA HDDs or SSDs or 4*3.5” SAS or SATA HDDSs. This server supports 2 GE ports without occupying any PCIe slots, improving network availability. Moreover, Dynamic energy-saving and power-capping technologies limit server power consumption to a preset threshold, improving overall energy efficiency.

Quick Specs

Figure 1 shows the appearance of Huawei RH 1288A V2 server.

The RH1288A V2 has the following two models:

The RH1288A V2-8S supports eight 2.5-inch SAS HDDs, SATA HDDs, or SSDs. Figure 1-1 shows the RH1288A V2-8S appearance.

The RH1288A V2-4L supports four 3.5-inch SAS or SATA HDDs. Figure 1-2 shows the RH1288A V2-4L appearance.

Figure 1-1  RH1288A V2-8S appearance. 

RH1288A V2-8S appearance

Figure 1-2  RH1288A V2-8S appearance.

RH1288A V2-4L appearance

Table 1 shows the Quick Specs.

Product

Huawei RH 1288A V2 server

Processors

1 or 2 Intel® Xeon® E5-2600 v2 series processors

Memory

8 DDR3 RDIMMs/LRDIMMs

Internal Storage

Hard disk configurations:

  • ● 8 x 2.5-inch SAS/SATA HDDs or SSDs
  • ● 4 x 3.5-inch SAS or SATA HDDs
  • RAID Support

  • ● RAID 0, 1, 10, 5, 50, 6, or 60
     
  • ● Supercapacitor
     
  • ● RAID state migration, configuration memory, self-diagnosis, and web-based remote configuration
  • LOM Network Ports

    Network configuration: 2 x GE electrical ports

    PCIe Expansion

    Up to 3 PCIe slots

    Fan Modules

    5 hot-swappable fan modules in N+1 redundancy mode; each fan module consists of two counter-rotating fans

    PSUs

    2 hot-swappable PSUs in 1+1 redundancy mode

    Management

    Uses Huawei Hi1710 management chip and independent ports, supports standard management interfaces, such as SNMP and IPMI, and provides a GUI, remote KVM, virtual media, SOL, Predictive Failure Analysis (PFA), intelligent power supply, remote control, and hardware monitoring
    Supports Huawei eSight management software and integration with third-party management systems, such as VMware vCenter, Microsoft SystemCenter, and Nagios

    Operating Temperature

    5ºC to 35ºC (41ºF to 95ºF)

     Product Details

    Figure 2 shows the front panel of Huawei RH 1288A V2 server.

    Figure 2-1  RH1288A V2-8S front view.

    RH1288A V2-8S front view.

    Note:

    UID button/indicator

    Power button/indicator

    USB port

    USB port

    Ethernet port indicator 1

    Ethernet port indicator 2

    Healthy indicator

    VGA port

    Hard disk

    ⑩ 

    Captive screw

    Hard disk fault indicator

    Hard disk active indicator

    Label (including the ESN label)

    Built-in DVD-ROM drive

    Hard disk slot label

     

     

    Figure 2-2  RH1288A V2-4L front view. 

    RH1288A V2-4L front view

    UID button/indicator

    Power button/indicator

    USB port

    USB port

    Ethernet port indicator 1

    Ethernet port indicator 2

    Healthy indicator

    Hard disk

    Captive screw

    ⑩ 

    Hard disk fault indicator

    Hard disk active indicator

    Label (including the ESN label)

    Hard disk slot label

     

    Figure 3 shows the back panel of Huawei RH 1288A V2 server.

    the back panel of Huawei RH 1288A V2 server

    Note:

    Connection status indicator

    GE port

    Data transmission status indicator

    GE port

    UID indicator

    Management network port (Mgmt)

    USB port

    USB port

    VGA port

    ⑩ 

    Serial port

    PSU power port

    PSU indicator

    PSU

    PSU power port

    PSU indicator

    16

    PSU

    Compare to Similar Items

    Table 3 shows the comparison of Huawei RH 1288A V2 server and Huawei RH1288 V2 Rack Server.

    Product

    Huawei RH 1288A V2 server

    Huawei RH1288 V2 Rack Server

    Processors

    1 or 2 Intel® Xeon® E5-2600 v2 series processors

    One or two Intel Xeon E5-2600 or E5-2600 v2 series processors

    Memory

    8 DDR3 RDIMMs/LRDIMMs

    24 DDR3 RDIMMs/LRDIMMs

    Internal Storage

    Hard disk configurations:

  • ● 8 x 2.5-inch SAS/SATA HDDs or SSDs
  • ● 4 x 3.5-inch SAS or SATA HDDs
  • Hard disk configurations:

  • ● 8 x 2.5-inch SAS/SATA HDDs or SSDs
  • ● 4 x 3.5-inch SAS or SATA HDDs
  • LOM Network Ports

    Network configuration: 2 x GE electrical ports

    Network configuration: two or four GE ports or two 10 GE ports

    Fan Modules

    5 hot-swappable fan modules in N+1 redundancy mode; each fan module consists of two counter-rotating fans

    Seven hot-swappable fan modules in N+1 redundancy mode
    Each fan module consists of two counter-rotating fans.

    Get more information

    Do you have any question about the Huawei RH 1288A V2 server

    Contact us now via Live Chat or Contact@huatenmax.com.

    Specification

    Huawei RH 1288A V2 server Specifications

    Technical Specifications

    Form factor

    1 U rack server

    Processor

    Up to two Intel® Xeon® E5-2600 v2 series processors:

    ·Number of cores per processor: 10 cores (2.4 GHz), 8 cores (2.6 GHz), 6 cores (2.6 GHz), and 4 cores (2.5 GHz)

    ·Number of QPI links: 2

    ·Maximum transmission speed per QPI link: 8.0 GT/s

    ·Maximum memory speed: 1866 MHz

    ·Maximum L3 cache capacity: 25 MB

    Up to two Intel® Xeon® E5-2600 series processors:

    ·Number of cores per processor: 8 cores (2.2 GHz), 6 cores (2.5 GHz), and 4 cores (2.4 GHz)

    ·Number of QPI links: 2

    ·Maximum transmission speed per QPI link: 8.0 GT/s

    ·Maximum memory speed: 1600 MHz

    ·Maximum L3 cache capacity: 20 MB

    Chipset

    Intel C602

    DIMM

    ·Up to 8 DIMM slots (4 DIMMs per processor) for installing either RDIMMs or LRDIMMs

    ·8 x 32 GB RDIMMs for two processors, with a maximum memory capacity of 256 GB

    ·8 x 32 GB LRDIMMs for two processors, with a maximum memory capacity of 256 GB

    ·Maximum memory speed: 1866 MHz (E5-2600 v2)

    ·Data protection measures: ECC, memory mirroring, Single Device Data Correction (SDDC), memory sparing, and lockstep

    Storage

    ·The RH1288A V2 supports the following hard disk configurations:

    ·RH1288A V2-8S: eight front 2.5-inch SAS HDDs (7.2 TB), SATA HDDs (8 TB), or SSDs (4.8 TB)

    ·RH1288A V2-4L: four front 3.5-inch SAS HDDs (4 TB) or SATA HDDs (16 TB)

    ·Hard disks are hot-swappable.

    ·The server supports RAID 0, 1, 10, 1E, 5, 50, 6, and 60. It protects cache data from power failures, and supports RAID state migration, RAID configuration memory, self-diagnosis, and web-based configuration.

    ·The mainboard can be configured with a SAS adapter or SAS RAID controller card (with a maximum of 1 GB cache) to improve hard disk storage performance and ensure user data security.

    ·The RAID controller card does not occupy a standard PCIe slot, improving system scalability.

    Network port

    Two GE ports (Intel I350) on the mainboard, supporting NC-SI, WOL, and PXE

    PCIe slot

    The server provides three PCIe slots: one for a full-height full-length PCIe card, one for a half-height half-length PCIe card, and one for a non-standard RAID controller card.

    One Huawei PCIe intelligent network interface card (iNIC), which improves the I/O bandwidth and throughput.

    One Huawei SSD card, which greatly improves I/O performance for search, cache, and download services.

    NVS315 GPU.

    Port

    Ports on the front panel:

    Two USB 2.0 ports

    One DB15 video port (provided by the RH1288A V2-8S)

    Ports on the rear panel:

    Two USB 2.0 ports

    One DB15 video port

    One DB9 serial port

    One RJ45 system management port

    One built-in USB port (for the embedded system management program)

    Fan module

    Five hot-swappable fan modules, tolerating the failure of a single fan. Each fan module consists of two counter-rotating fans.

    PSU

    Two hot-swappable 460 W AC PSU in redundancy mode, supporting efficiency of up to 94 percent.

    System management

    UEFI

    Huawei iBMC: supports Intelligent Platform Management Interface (IPMI), Serial over LAN (SOL), KVM over IP, and virtual media, and provides one 10/100/1000M RJ-45 management network port.

    NC-SI

    Security

    Power-on password

    Administrator password

    GPU

    The mainboard integrates the SM750 display chip and provides 32 MB display memory. The maximum resolution is 1920 pixels x 1200 pixels at 60 Hz with 16 M colors.

    Physical Specifications

    Dimensions (H x W x D)

    43.6 mm x 447 mm x 740 mm (1.78 in. x 17.05 in. x 29.13 in.)

    Installation dimensions

    The RH1288A V2 fits into a common rack complying with the IEC 297 standard.

    Rack width: 19 in.

    Rack depth: > 1000 mm (39.37 in.)

    Guide rail installation requirements are as follows:

    L-shaped guide rails: apply only to Huawei racks.

    Adjustable guide rail: The distance between the front rear mounting bars is 557 mm to 862 mm.

    Power rating

    460 W

    Weight in full configuration

    Net weight:

    RH1288A V2-8S: 19.6 kg

    RH1288A V2-4L: 20 kg

    Packaging materials: 5.3 kg (11.69 lb)

    Input voltage

    AC: 100-240 V AC (with an input frequency of 50 Hz or 60 Hz)

    240 V HV DC: 192-288 V DC

    NOTE:

    The recommended current specification for the external power circuit breaker connected to the RH1288A V2 is 32 A.

    Temperature

    Operating temperature: 5°C to 35°C (41°F to 95°F)

    Storage temperature: –40°C to +65°C (–40ºF to +149ºF)

    Temperature change rate: < 20°C/h (36°F/h)

    Long-term storage temperature: 21°C to 27°C (69.8°F to 80.6°F)

    Altitude

    ≤ 3000 m (9842.40 ft) When the altitude is higher than 900 m (2952.72 ft), the operating temperature decreases by 1°C (33.8°F) per 300 m (984.24 ft).

    Humidity

    Operating humidity: 8% RH to 90% RH (non-condensing)

    Storage humidity: 5% RH to 95% RH (non-condensing)

    Humidity change rate: < 20% RH/hour

    Long-term storage humidity: 30% RH to 69% RH (non-condensing)

    Acoustic Noise

    The data listed in the following is the declared A-weighted sound power levels (LWAd) and declared average bystander position A-weighted sound pressure levels (LpAm) when the server is operating in a 23°C (73.4°F) ambient environment. Noise emissions are measured in accordance with ISO 7999 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109).

    Idle:

    LWAd: 5.9Bels

    LpAm: 43dBA

    Operating:

    LWAd: 6.7Bels

    LpAm: 50.1dBA

    NOTE:

    The actual sound levels generated during server operating vary depending on the server configuration, load, and ambient temperature.

     

     

    Products Tags

    Follow us and the future of network

    Follow us, you will get the latest products and industry information in our insights emails.
    Subscribe now also can get more than 50 valuable white papers. Learn Details>>>