Huawei RH1288A V2 rack server is designed for compute intensive and cloud applications. This high-performance 1U rack server supports 2 Intel Xeon E5-2600 V2 series processors, 8*DDR3 RDIMMs/LRDIMMS slots, 8*2.5” SAS/SATA HDDs or SSDs or 4*3.5” SAS or SATA HDDSs. This server supports 2 GE ports without occupying any PCIe slots, improving network availability. Moreover, Dynamic energy-saving and power-capping technologies limit server power consumption to a preset threshold, improving overall energy efficiency.
Figure 1 shows the appearance of Huawei RH 1288A V2 server.
The RH1288A V2 has the following two models:
The RH1288A V2-8S supports eight 2.5-inch SAS HDDs, SATA HDDs, or SSDs. Figure 1-1 shows the RH1288A V2-8S appearance.
The RH1288A V2-4L supports four 3.5-inch SAS or SATA HDDs. Figure 1-2 shows the RH1288A V2-4L appearance.
Figure 1-1 RH1288A V2-8S appearance.
Figure 1-2 RH1288A V2-8S appearance.
Table 1 shows the Quick Specs.
Product |
|
Processors |
1 or 2 Intel® Xeon® E5-2600 v2 series processors |
Memory |
8 DDR3 RDIMMs/LRDIMMs |
Internal Storage |
Hard disk configurations: |
RAID Support |
|
LOM Network Ports |
Network configuration: 2 x GE electrical ports |
PCIe Expansion |
Up to 3 PCIe slots |
Fan Modules |
5 hot-swappable fan modules in N+1 redundancy mode; each fan module consists of two counter-rotating fans |
PSUs |
2 hot-swappable PSUs in 1+1 redundancy mode |
Management |
Uses Huawei Hi1710 management chip and independent ports, supports standard management interfaces, such as SNMP and IPMI, and provides a GUI, remote KVM, virtual media, SOL, Predictive Failure Analysis (PFA), intelligent power supply, remote control, and hardware monitoring |
Operating Temperature |
5ºC to 35ºC (41ºF to 95ºF) |
Figure 2 shows the front panel of Huawei RH 1288A V2 server.
Figure 2-1 RH1288A V2-8S front view.
Note:
① |
UID button/indicator |
② |
Power button/indicator |
③ |
USB port |
④ |
USB port |
⑤ |
Ethernet port indicator 1 |
⑥ |
Ethernet port indicator 2 |
⑦ |
Healthy indicator |
⑧ |
VGA port |
⑨ |
Hard disk |
⑩ |
Captive screw |
Hard disk fault indicator |
Hard disk active indicator |
||
Label (including the ESN label) |
Built-in DVD-ROM drive |
||
Hard disk slot label |
|
|
Figure 2-2 RH1288A V2-4L front view.
① |
UID button/indicator |
② |
Power button/indicator |
③ |
USB port |
④ |
USB port |
⑤ |
Ethernet port indicator 1 |
⑥ |
Ethernet port indicator 2 |
⑦ |
Healthy indicator |
⑧ |
Hard disk |
⑨ |
Captive screw |
⑩ |
Hard disk fault indicator |
Hard disk active indicator |
Label (including the ESN label) |
||
Hard disk slot label |
|
Figure 3 shows the back panel of Huawei RH 1288A V2 server.
Note:
① |
Connection status indicator |
② |
GE port |
③ |
Data transmission status indicator |
④ |
GE port |
⑤ |
UID indicator |
⑥ |
Management network port (Mgmt) |
⑦ |
USB port |
⑧ |
USB port |
⑨ |
VGA port |
⑩ |
Serial port |
PSU power port |
PSU indicator |
||
PSU |
PSU power port |
||
PSU indicator |
16 |
PSU |
Table 3 shows the comparison of Huawei RH 1288A V2 server and Huawei RH1288 V2 Rack Server.
Product |
||
Processors |
1 or 2 Intel® Xeon® E5-2600 v2 series processors |
One or two Intel Xeon E5-2600 or E5-2600 v2 series processors |
Memory |
8 DDR3 RDIMMs/LRDIMMs |
24 DDR3 RDIMMs/LRDIMMs |
Internal Storage |
Hard disk configurations: |
Hard disk configurations: |
LOM Network Ports |
Network configuration: 2 x GE electrical ports |
Network configuration: two or four GE ports or two 10 GE ports |
Fan Modules |
5 hot-swappable fan modules in N+1 redundancy mode; each fan module consists of two counter-rotating fans |
Seven hot-swappable fan modules in N+1 redundancy mode |
Do you have any question about the Huawei RH 1288A V2 server
Contact us now via Live Chat or Contact@huatenmax.com.
Huawei RH 1288A V2 server Specifications |
||
Technical Specifications |
||
Form factor |
1 U rack server |
|
Processor |
Up to two Intel® Xeon® E5-2600 v2 series processors: ·Number of cores per processor: 10 cores (2.4 GHz), 8 cores (2.6 GHz), 6 cores (2.6 GHz), and 4 cores (2.5 GHz) ·Number of QPI links: 2 ·Maximum transmission speed per QPI link: 8.0 GT/s ·Maximum memory speed: 1866 MHz ·Maximum L3 cache capacity: 25 MB Up to two Intel® Xeon® E5-2600 series processors: ·Number of cores per processor: 8 cores (2.2 GHz), 6 cores (2.5 GHz), and 4 cores (2.4 GHz) ·Number of QPI links: 2 ·Maximum transmission speed per QPI link: 8.0 GT/s ·Maximum memory speed: 1600 MHz ·Maximum L3 cache capacity: 20 MB |
|
Chipset |
Intel C602 |
|
DIMM |
·Up to 8 DIMM slots (4 DIMMs per processor) for installing either RDIMMs or LRDIMMs ·8 x 32 GB RDIMMs for two processors, with a maximum memory capacity of 256 GB ·8 x 32 GB LRDIMMs for two processors, with a maximum memory capacity of 256 GB ·Maximum memory speed: 1866 MHz (E5-2600 v2) ·Data protection measures: ECC, memory mirroring, Single Device Data Correction (SDDC), memory sparing, and lockstep |
|
Storage |
·The RH1288A V2 supports the following hard disk configurations: ·RH1288A V2-8S: eight front 2.5-inch SAS HDDs (7.2 TB), SATA HDDs (8 TB), or SSDs (4.8 TB) ·RH1288A V2-4L: four front 3.5-inch SAS HDDs (4 TB) or SATA HDDs (16 TB) ·Hard disks are hot-swappable. ·The server supports RAID 0, 1, 10, 1E, 5, 50, 6, and 60. It protects cache data from power failures, and supports RAID state migration, RAID configuration memory, self-diagnosis, and web-based configuration. ·The mainboard can be configured with a SAS adapter or SAS RAID controller card (with a maximum of 1 GB cache) to improve hard disk storage performance and ensure user data security. ·The RAID controller card does not occupy a standard PCIe slot, improving system scalability. |
|
Network port |
Two GE ports (Intel I350) on the mainboard, supporting NC-SI, WOL, and PXE |
|
PCIe slot |
The server provides three PCIe slots: one for a full-height full-length PCIe card, one for a half-height half-length PCIe card, and one for a non-standard RAID controller card. One Huawei PCIe intelligent network interface card (iNIC), which improves the I/O bandwidth and throughput. One Huawei SSD card, which greatly improves I/O performance for search, cache, and download services. NVS315 GPU. |
|
Port |
Ports on the front panel: Two USB 2.0 ports One DB15 video port (provided by the RH1288A V2-8S) Ports on the rear panel: Two USB 2.0 ports One DB15 video port One DB9 serial port One RJ45 system management port One built-in USB port (for the embedded system management program) |
|
Fan module |
Five hot-swappable fan modules, tolerating the failure of a single fan. Each fan module consists of two counter-rotating fans. |
|
PSU |
Two hot-swappable 460 W AC PSU in redundancy mode, supporting efficiency of up to 94 percent. |
|
System management |
UEFI Huawei iBMC: supports Intelligent Platform Management Interface (IPMI), Serial over LAN (SOL), KVM over IP, and virtual media, and provides one 10/100/1000M RJ-45 management network port. NC-SI |
|
Security |
Power-on password Administrator password |
|
GPU |
The mainboard integrates the SM750 display chip and provides 32 MB display memory. The maximum resolution is 1920 pixels x 1200 pixels at 60 Hz with 16 M colors. |
|
Physical Specifications |
||
Dimensions (H x W x D) |
43.6 mm x 447 mm x 740 mm (1.78 in. x 17.05 in. x 29.13 in.) |
|
Installation dimensions |
The RH1288A V2 fits into a common rack complying with the IEC 297 standard. Rack width: 19 in. Rack depth: > 1000 mm (39.37 in.) Guide rail installation requirements are as follows: L-shaped guide rails: apply only to Huawei racks. Adjustable guide rail: The distance between the front rear mounting bars is 557 mm to 862 mm. |
|
Power rating |
460 W |
|
Weight in full configuration |
Net weight: RH1288A V2-8S: 19.6 kg RH1288A V2-4L: 20 kg Packaging materials: 5.3 kg (11.69 lb) |
|
Input voltage |
AC: 100-240 V AC (with an input frequency of 50 Hz or 60 Hz) 240 V HV DC: 192-288 V DC NOTE: The recommended current specification for the external power circuit breaker connected to the RH1288A V2 is 32 A. |
|
Temperature |
Operating temperature: 5°C to 35°C (41°F to 95°F) Storage temperature: –40°C to +65°C (–40ºF to +149ºF) Temperature change rate: < 20°C/h (36°F/h) Long-term storage temperature: 21°C to 27°C (69.8°F to 80.6°F) |
|
Altitude |
≤ 3000 m (9842.40 ft) When the altitude is higher than 900 m (2952.72 ft), the operating temperature decreases by 1°C (33.8°F) per 300 m (984.24 ft). |
|
Humidity |
Operating humidity: 8% RH to 90% RH (non-condensing) Storage humidity: 5% RH to 95% RH (non-condensing) Humidity change rate: < 20% RH/hour Long-term storage humidity: 30% RH to 69% RH (non-condensing) |
|
Acoustic Noise |
The data listed in the following is the declared A-weighted sound power levels (LWAd) and declared average bystander position A-weighted sound pressure levels (LpAm) when the server is operating in a 23°C (73.4°F) ambient environment. Noise emissions are measured in accordance with ISO 7999 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109). Idle: LWAd: 5.9Bels LpAm: 43dBA Operating: LWAd: 6.7Bels LpAm: 50.1dBA NOTE: The actual sound levels generated during server operating vary depending on the server configuration, load, and ambient temperature. |
|