Quick Quote ico
  • S5320-36C-EI-28S-AC
  • S5320-36C-EI-28S-AC

S5320-36C-EI-28S-AC

Model:S5320-36C-EI-28S-AC Huawei S5300 Series Switch
HuatenMax

Expertise Builds Trust

100+ Countries

6000+ Customers/Projects

CCIE, CISSP, JNCIE, NSE 7 AWS, Google Cloud Experts

Jim Huang

+86 136 9226 0946

Contact@huatenmax.com

Overview

Huawei S5300 Series Switch S5320-36C-EI-28S-AC 28 Gig SFP,4 of which are dual-purpose 10/100/1000 or SFP,4 10 Gig SFP+, with 1 interface slot, with 150W AC power supply, stackable, Enhanced layer 3 feature.

Quick Specs

Figure 1 shows the appearance of S5320-36C-EI-28S-AC.

the appearance of S5320-36C-EI-28S-AC

Table 1 shows the Quick Specs.

Product Code

S5320-36C-EI-28S-AC

Packet forwarding rate

132 Mpps

Fixed ports

28x100/1000Base-X SFP ports, 4x combo 10/100/1000BaseT

Ethernet ports, and 4x10G SFP+ ports

Extended slot

One extended slot that

supports an uplink interface

card or private stack card

Front power

input

No

Mean time between

failures (MTBF)

85.45 years without card; 78.2 years when a 2x10GE SFP+ card is configured; 75.87 years when a 2x10GE RJ45 card is configured; 76.05 years when a stack card is configured

Memory

2 GB

Flash

340 MB

Available Version

V200R007C00 and later versions

Input voltage

AC:

Rated voltage range: 100 V to 240 V AC, 50/60 Hz

Maximum voltage range: 90 to 264 V AC, 47/63 Hz

Maximum power

consumption (100%

throughput, full

speed of fans)

83.9 W

Dimensions (W x D x H)

442.0 mm x 420.0 mm x 43.6 mm

Weight

Fully loaded ≤ 12 kg

Empty chassis ≤ 8 kg

Product Details

Figure 2 shows the front panel of S5320-36C-EI-28S-AC.

the front panel of S5320-36C-EI-28S-AC

Note:

Twenty-four 100/1000BASE-X Ethernet optical ports

Applicable modules:

  • ● FE optical module
  • ● GE optical module
  • ● GE-CWDM optical module
  • ● GE copper module

Four combo ports (10/100/1000BASE-T + 100/1000BASE-X) Modules applicable to combo optical ports:

  • ● FE optical module
  • ● GE optical module
  • ● GE-CWDM optical module

Four 10GE SFP+ Ethernet optical ports

Applicable modules and cables:

  • ● GE optical module
  • ● GE-CWDM optical module
  • ● GE-DWDM optical module
  • ● GE SFP copper module
  • ● 10GE SFP+ optical module
  • ● 10GE-CWDM optical module (applicable in V200R005C00 and later versions)
  • ● 1 m, 3 m, 10 m SFP+ copper cables
  • ● 3 m, 10 m AOC cables

One Mini USB port

One console port

One ETH management port

One USB port

Figure 3 shows the back panel of S5320-36C-EI-28S-AC.

the back panel of S5320-36C-EI-28S-AC

Note:

Ground screw

NOTE: It is used with a ground cable.

Equipment serial number (ESN) label

NOTE: You can draw it out to view the ESN and MAC address of the switch.

Extended card slot

Applicable cards:

Fan module slot

Applicable fan module: FAN-028B-B

Power module slot 2

Applicable power modules:

  • ● 150 W AC power module
  • ● 150 W DC power module

Power module slot 1

Applicable power modules:

  • ● 150 W AC power module
  • ● 150 W DC power module

The Modules

Table 2 shows the recommended elements for the S5320-36C-EI-28S-AC.

Model

Description

FE-SFP Optical Transceiver

SFP-FE-SX-MM1310

Optical Transceiver, SFP, 100M/155M, Multi-mode Module(1310nm, 2km, LC)

eSFP-FE-LX-SM1310

Optical Transceiver, eSFP, 100M/155M, Single-mode Module(1310nm, 15km, LC)

S-SFP-FE-LH40-SM1310

Optical Transceiver, eSFP, FE, Single-mode Module(1310nm, 40km, LC)

GE-SFP Optical Transceiver

eSFP-GE-SX-MM850

Optical Transceiver, eSFP, GE, Multi-mode Module(850nm, 0.55km, LC)

SFP-GE-LX-SM1310

Optical Transceiver, eSFP, GE, Single-mode Module(1310nm, 10km, LC)

S-SFP-GE-LH40-SM1310

Optical Transceiver, eSFP, GE, Single-mode Module(1310nm, 40km, LC)

S-SFP-GE-LH40-SM1550

Optical Transceiver, eSFP, GE, Single-mode Module(1550nm, 40km, LC)

10G-SFP+ Optical Transceiver

SFP-10G-USR

10GBase-USR Optical Transceiver, SFP+, 10G, Multi-mode Module(850nm, 0.1km, LC)

OMXD30000

Optical Transceiver, SFP+, 10G, Multi-mode Module(850nm, 0.3km, LC)

OSX010000

Optical Transceiver, SFP+, 10G, Single-mode Module(1310nm, 10km, LC)

GE Copper Transceiver

SFP-1000BaseT

Electrical Transceiver, SFP, GE, Electrical Interface Module(100m, RJ45)

Compare to Similar Items

Table 3 shows the comparison of S5320-36C-EI-28S-AC and S5320-32X-EI-24S-DC.

Product Code

S5320-36C-EI-28S-AC

S5320-32X-EI-24S-DC

Packet forwarding rate

132 Mpps

102 Mpps

Fixed ports

28x100/1000Base-X SFP ports, 4x combo 10/100/1000BaseT

Ethernet ports, and 4x10G SFP+ ports

24x100/1000Base-X SFP ports, 4x10/100/1000Base-T

Ethernet ports, and 4 10G SFP+ ports

Extended slot

One extended slot that

supports an uplink interface

card or private stack card

NA

Front power

input

No

Yes

Mean time between

failures (MTBF)

85.45 years without card; 78.2 years when a 2x10GE SFP+ card is configured; 75.87 years when a 2x10GE RJ45 card is configured; 76.05 years when a stack card is configured

82.54 years

Memory

2 GB

2 GB

Flash

340 MB

340 MB

Input voltage

AC:

Rated voltage range: 100 V to 240 V AC, 50/60 Hz

Maximum voltage range: 90 to 264 V AC, 47/63 Hz

DC:

Rated voltage range: –48 V to –60 V DC

Maximum voltage range: –36 V to –72 V DC

Maximum power

consumption (100%

throughput, full

speed of fans)

83.9 W

58.9 W

Get more information

Do you have any question about the S5320-36C-EI-28S-AC?

Contact us now via Live Chat or Contact@huatenmax.com.

Specification

S5320-36C-EI-28S-AC Specification

Fixed Ports

28×100/1000Base-X(4GE Combo), 4×10 Gig SFP+  

Extended slot

 

One extended slot that supports an uplink interface card or private stack card  

MAC Address Table

IEEE 802.1d

64K MAC address entries

MAC address learning and aging

Static, dynamic, and blackhole MAC address entries

Packet filtering based on source MAC addresses

VLAN Features

4K VLANs

Guest VLAN and voice VLAN

GVRP

MUX VLAN

VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports

1:1 and N:1 VLAN mapping

VLAN-based transparent transmission of protocol packets

Jumbo frame

12K

 

Ring protection

 

RRPP ring topology and RRPP multi-instance

Smart Link tree topology and Smart Link multi-instance, providing millisecond-level protection switchover

Smart Ethernet Protection (SEP),G.8032 Ethernet Ring Protection Switching (ERPS)

STP (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s)

VLAN-based Spanning Tree (working with PVST/PVST+/RPVST)

BPDU protection, root protection, and loop protection

BPDU tunnel

IP routing

 

Static routing, RIPv1/2, RIPng, OSPF, OSPFv3, IS-IS, IS-ISv6, BGP, BGP4+, ECMP, and policy-based routing

IPv6 features

Neighbor Discovery (ND)

Path maximum transmission unit (PMTU)

IPv6 Ping, IPv6 Tracert, and IPv6 Telnet

6 to4 tunnel, ISATAP tunnel, and manually configured tunnel

ACLs based on source IPv6 addresses, destination IPv6 addresses, Layer 4 ports, or protocol types

Multicast Listener Discovery (MLD) v1/v2 snooping

Multicast forwarding

 

IGMP v1/v2/v3 snooping and IGMP fast leave

Multicast forwarding in a VLAN and multicast replication between VLANs

Multicast load splitting among trunk member ports

Controllable multicast

Layer 2 multicast control

Port-based multicast traffic statistics collection

IGMPv1/v2/v3, Protocol Independent Multicast Sparse Mode (PIM-SM), and Protocol Independent Multicast Dense Mode (PIM-DM), and Protocol Independent Multicast Source-Specific Multicast (PIM-SSM)

Multicast Source Discovery Protocol (MSDP)

QoS/ACL

 

Inbound and outbound traffic rate limiting on a port

Packet redirection

Broadcast storm control

Port-based traffic policing and two-rate and three-color CAR

Eight queues per port,Weighted round robin (WRR), deficit round robin (DRR),

strict priority (SP), WRR+SP, and DRR+SP queue scheduling algorithms

Weighted random early detection (WRED)

Re-marking of the 802.1p priority and DSCP value of packets

Packet filtering based on Layer 2 to Layer 4 information, including source MAC addresses, destination MAC addresses, source IP addresses, destination IP addresses, TCP/UCD source/destination ports, protocol types, and VLAN IDs

Per queue rate limiting and interface traffic shaping

1:1,N:1,N:4 port mirroring

VLAN mirroring

 

Security features

 

Hierarchical user management and password protection

DoS attack defense, ARP attack defense, and ICMP attack defense

Binding of the IP address, MAC address, interface number, and VLAN ID of a user

Port isolation, port security, and sticky MAC

MAC Forced Forwarding (MFF)

Blackhole MAC address entries

Limit on the number of learned MAC addresses

IEEE 802.1x authentication and the limit on the number of users on an interface

AAA authentication, RADIUS authentication, HWTACACS+ authentication, and NAC

SSH v2.0

Hypertext Transfer Protocol Secure (HTTPS)

CPU defense

Blacklist and whitelist

Access security

 

DHCP Relay

DHCP Server

DHCP Snooping

DHCP Client

DHCP Security

Port aggregation

 

LACP

Up to 64 trunk groups

Up to 8 member interfaces in each trunk group

Reliability

Ethernet OAM (IEEE 802.3ah and 802.1ag)

ITU-Y.1731

BFD for BGP/IS-IS/OSPF/static route

Management and Maintenance

iStack

Virtual cable test

SNMPv1/v2/v3

RMON/RMON2

Web-based network management system

System logs and multi-level alarms

sFlow

LLDP/LLDP-MED

SCP (Secure Copy Protocol), TFTP, FTP

Store dual software images and configuration files

802.3az Energy Efficient Ethernet (EEE)

Operating Environment

Operating temperature:

0-1800 m altitude: 0-45°C

1800-5000 m altitude: The operating temperature reduces by 1°C every time the altitude increases by 220 m.

Relative humidity: 5% to 95% (noncondensing)

Input Voltage

AC:

Rated voltage range: 100 V to 240 V AC, 50/60 Hz

Maximum voltage range: 90 to 264 V AC, 47/63 Hz

Front power input

No

Dimensions (W x D x H)

442 x 420 x 43.6

Power Consumption

<83.9W

Products Tags

Follow us and the future of network

Follow us, you will get the latest products and industry information in our insights emails.
Subscribe now also can get more than 50 valuable white papers. Learn Details>>>